1.9.3.2 Moisture Image Series Probes (MISP and MISP2)
Connect the Moisture Image Series probes ( MISP ) to the moisture.IQ using the cable provided. You can locate a
Moisture Image Series probe up to 915 m (3000 ft) from the electronics unit.
Note: Sale of the MISP probe was discontinued by BHGE in 2010 and it was replaced by the MISP2 probe.
Although the MISP probe can be used successfully with the moisture.IQ analyzer, there may be
communication issues when using long cables.
Before making any electrical connections, you must assemble the probe. A Moisture Image Series probe may be
shipped in two parts: a probe and an electronics module , each of which has its own serial number. If you
ordered more than one probe, be sure to match each probe to its matching electronics module using the serial
numbers listed on the probe Calibration Data Sheet. To assemble a Moisture Image Series probe, insert the
probe into the probe connector on the matching electronics module and turn the probe counterclockwise until
it locks in place (see Figure 14 below).
CAUTION! The MISP2 probe has an integral set of electronics permanently attached (see Figure 15
below). Do not attempt to separate an MISP2 probe from its electronics.
moisture.IQ User's Manual
Connector
Figure 14: Moisture Image Series Probe (MISP) Assembly
Figure 15: MISP2 Probe
Chapter 1. Installation
19