SYSTEM General #1 page ([SYSTEM] -
[F1 (General)])
Master
Level (Master Level)
Range: 0–127
Adjusts the volume of the entire XV-5080.

Example of Settings

Selecting Different Output Destinations
for Parts in a Performance
This example describes the procedure for outputting Part 1
from the A (MIX) OUTPUT jacks without sending it through
any internal effects, sending Part 2 through the Multi-effects
A and then outputting it from the B OUTPUT jack, and
outputting Part 3 from the INDIVIDUAL 5 OUTPUT jack
without sending it through any internal effects.
First, set Part 1.
1. Select the Performance you wish to use.
2. Press [F6 (Effects)].
3. Press [F1 (General)] several times to call up the
Performance Effects General #1 page.
4. Press PART SELECT [1/17] to make its indicator light.
* Make sure that the [1-16/17-32] button's indicator is not lit. If
the indicator is lit, press [1-16/17-32] to turn it off.
5. Press [
]/[
]/[
Part Output Assign.
6. Turn the VALUE dial or press [INC]/[DEC] to select
"A."
7. Press [
]/[
]/[
Part Dry Send Level.
8. Turn the VALUE dial to select "100."
9. Press [
]/[
]/[
Part Chorus Send Level.
10. Turn the VALUE dial to select "0."
11. Set the Part Reverb Send Level setting to "0" in the same
way.
Next, set up Part 2.
12. Press PART SELECT [2/18], getting its indicator to light.
* Make sure that the [1-16/17-32] button's indicator is not lit. If
the indicator is lit, press [1-16/17-32] to turn it off.
]/[
] to move the cursor to
]/[
] to move the cursor to
]/[
] to move the cursor to
Chapter 3 Selecting Output Jacks
13. Press [
]/[
]/[
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
Part Output
Part Dry
Assign
Send Level
MFX-A
100
The Part Dry Send Level can be set to any value you wish
other than 0.
14. Press [
]/[
]/[
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
MFX
MFX Dry
Output Assign
Level
B
100
Finally, set up Part 3.
15. Press PART SELECT [3/19], getting its indicator to light.
* Make sure that the [1-16/17-32] button's indicator is not lit. If
the indicator is lit, press [1-16/17-32] to turn it off.
16. Press [
]/[
]/[
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
Part Output
Part Chorus
Assign
Send Level
5
The output level can be set to any value you wish other than
0.
17. Press [EXIT] to return to the PERFORM PLAY page.
]/[
] to move the cursor to
Part Chorus
Part Reverb
Send Level
Send Level
0
0
]/[
] to move the cursor to
MFX Chorus
MFX Reverb
Send Level
Send Level
0
0
]/[
] to move the cursor to
Part Reverb
Send Level
0
0