Loading Data Stored On Memory Cards; Sample-Related Utilities; Sending And Receiving Samples (Sample Dump) - Roland XV-5080. Owner's Manual

Roland owner's manual 128-voice 8x expansion/sample playback xv-5080
Hide thumbs Also See for XV-5080.:
Table of Contents

Advertisement

You can also sort files. When you press [F3 (Sort)] the
window for selecting the type of sort is displayed. Turn the
VALUE dial or press [
] or [
want the files to be sorted, then press [F6 (OK)].
Without:
Files appear in the order saved.
Name:
Files are sorted according to the file names.
: Files are sorted in ascending order of file size.
Size
Size
:
Files are sorted in descending order of file size.
4. Press [F6 (Load)].
A message saying, "Overwriting to the User Group. OK?"
appears, and a window showing the User Group Patch and
Performance numbers to be overwritten is displayed.
* If you want to cancel, press [EXIT].
* When Patches/Performances/Rhythm Sets are loaded
individually, only the lower-level data essential to production
of the sound will be loaded at the same time.
This is convenient when creating an overall XV-5080 settings
file (.SVD) that fits the capacity of the SIMMs you actually
have installed.
Loading Data Stored on
Memory Cards
Data (.SVD) files stored on memory cards holding the Patch,
Performance, Rhythm Set, and system settings are loaded to
the internal memory. The memory is overwritten when the
file is loaded (all wave data in the Sample folder is loaded
into the SIMM as well). Should there be any data in internal
memory you want to keep, be sure to save it onto a memory
card before you begin the load procedure.
1. Press [DISK].
2. Press [F1 (Load)].
3. Press [F1 (Drive)].
4. Turn the VALUE dial and select "CARD."
5. Press [F6 (OK)].
The contents of the card are displayed.
6. Turn the VALUE dial and select the file you want to load.
7. Move the cursor to the file to be loaded (.SVD) and press
[F6 (Select)].
8. Press [F6 (Load)].
] to select the way you
Chapter 7 Loading a Variety of Data
All of the XV-5080 settings for the selected file, with values as
they were when saved, are loaded.
* If any samples are used in the file being loaded, a confirmation
message appears, asking whether or not you want to overwrite
the data (Partials/Waves) already contained in the SIMM.
Press [F6 (OK)] to proceed with the load. To cancel, press
[EXIT].
* If you want to load only a part of the data in the file, refer to
"Individually Loading Patches, Performances, or Rhythm Sets
(p. 190)" and "Transmitting to User Memory (p. 204)."
* Although you can directly call up Patches, Performances, and
Rhythm Sets on a memory card using Program Change
messages, panel controls or MIDI Exclusive messages cannot
be used to perform editing. For editing, you need to transfer
the data to internal memory first.

Sample-Related Utilities

Sending and Receiving Samples
(Sample Dump)
You can transmit and receive wave data using the Sample
Dump MIDI Universal Exclusive Message. Samples (wave
data) including loop points and loop modes can be
exchanged with samplers supporting the Sample Dump
Standard.
* Sample name and key-range data is not transmitted. Set this
separately on the receiving sampler.
* Data received by the XV-5080 automatically has
"MIDI******" added to the name.
Transmitting Samples
1. Connect the XV-5080 and the receiving sampler with a
MIDI cable.
For instructions on making settings for the receiving
sampler, refer to the owner's manual for the connected
device.
2. Press [SYSTEM/UTILITY], getting its indicator to start
blinking.
* If the indicator is steadily lit, you are in SYSTEM mode. Press
[SYSTEM/UTILITY] once again, so the indicator is blinking.
3. Press [F6 (Menu)] to select Menu 2.
4. Press the [F2 (S-Dump)] button.
The Sample Dump Standard page appears.
191

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents