Chapter 3 Selecting Output Jacks
Synchronizing the XV-5080 to the Word Clock arriving at
WORD CLOCK IN
fig.RBUS-6.e
Settings
• XV-5080 Settings
Master Clock: WORD CLOCK IN
• Word Clock Master Device Settings
Set the sampling rate for the device acting as Word Clock Master to 44.1 or 48.0 kHz.
* Word Clock signals input at WORD CLOCK IN are output through R-BUS and S/P DIF.
124
VM-3100Pro
R-BUS
W
Word Clock
WORD CLOCK MASTER
W
WORD CLOCK OUT
XV-5080
WORD CLOCK IN
W