Unit. Use of an external lightning arrestor will reduce the cable length by 10 m.
Table 3.22 — Maximum allowed cable lengths for MPT Extended Power Unit (MPR-A)
Cable type
Configuration
Power
Requirement
42 W
1
MPT-MC/HC
MPT-HC with
48 W
1
XPIC
MPT-HC-
39.5 W
1
HQAM
MPT-HC-HQAM
40.5 W
1
with XPIC
77 W
1
MPT-XP
MPT-XP with
83 W
1
XPIC
MPT-XP-
75 W
1
HQAM
MPT-XP-HQAM
76 W
1
with XPIC
Constraint 1
Constraint 2
Constraint 3
1.Equipped with SFP
120
provides the maximum cable lengths for use with an MPT Extended Power
Cat5E, 1AC016760006:
Power and data
on Ethernet cable
Maximum length
100 m
100 m
100 m
100 m
40 m
40 m
40 m
40 m
Maximum current in Ethernet transformer < 1.8 A
Maximum current limit for Power Unit: 1.8 A
Minimum MPT-HC/HC-HQAM PSU input voltage > -28 V, Minimum MPT-XP/
XP-HQAM PSU input voltage > -41 V
Data traffic only with
Ethernet cable
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
Cat5E, 1AC016760006:
Power only, data
on optical cable
Maximum length
100 m
100 m
100 m
100 m
100 m
100 m
100 m
100 m
Data traffic only with
optical cable
Coaxial cable
1AB350440001:
Power only, data
on optical cable
Maximum length
300 m
300 m
300 m
300 m
300 m
300 m
300 m
300 m
Maximum current limit
for Power Unit: 1.8 A
Data traffic only with
optical cable