Figure 4.135 - Counters Thresholds - Alcatel-Lucent 9500 User Manual

Microwave packet radio for ansi and etsi
Hide thumbs Also See for 9500:
Table of Contents

Advertisement

Navigator area
4.9.2.2.1 — Counters thresholds
In the Counters Thresholds screen the Low Threshold and High Threshold can be
changed for each G.826 parameter (BBE, ES, SES). The high threshold will cause the
activation of a Threshold exceeded alarm during the Performance Monitoring period and
the low threshold will cause the deactivation of the same alarm.
Note: For the 24-hour report only the High Threshold can be changed.
Click on the Apply button to send the new parameters to the equipment.
Click on the Default button to restore the default parameters.
4.9.2.2.2 — 15Min counters
The upper part of the screen will show the values of the current 15-min period; the lower
part will show the last elapsed 15-min period.
Click on the Activate button (1) to activate the 15-min normalized NE counter
computation.
304
Figure 4.135 — Counters thresholds
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01