The MPR-e can be connected to the MSS-1c using electrical connectivity through the User
Port 2 (SynchE capability) or using optical connectivity through an optical SFP plugged on
User Port 4 or User Port 3 (not available on MSS-1c variant) (both SynchE capability).
A DC Power Injector box or MPT Extended Power Unit should be used to power the MPR-
e (refer to the User Manual of MPR-e for detailed information).
The speed of the MSS-1c User Port, on which the MPR-e is connected, must be set to 1000
Mb/s with SynchE enabled.
3.6 — Typical system configurations for MSS-1c
TDM over Ethernet packet node - mapping of E1/T1/DS1 TDM on Ethernet
Note: In this case a connected MPT is needed in order to configure the cross-connections.
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01

Typical system configurations for MSS-1c

Figure 3.36 — 2x(1+0) repeater configuration
(Figure
3.37).