MPR-E: Termination of 10E1 or 16E1 signals (E1 bi-directional interfaces according
ITU-T G.703 on the front panel)
•
MPR-A: Termination of 16T1 signal with MSS-1c 16PDH variant (T1 bi-directional
interfaces according to ANSI T1.403/TR 62411 on the front panel)
•
Encapsulation/Extraction of those PDH data flows into/from standard Ethernet
packets Inter Working Function
•
Reconstruction of the original PDH Timing
•
Sending/getting those std Ethernet packets to the Ethernet switch
•
Communication with the Controller for provisioning and status report.
3.10.1.6 — MPT interface
The MPT Interface is the interface for one MPT: MPT-HC/HC V2/HC-HQAM/MC/XP/
XP-HQAM/9558HC.
For interconnections with MSS-1c, see
interconnection,
MC
interconnection.
3.10.1.6.1 — Main functions
•
Provide the power supply interface and the Ethernet interface
•
Provide the Power Feed over Ethernet function
•
Lightning and surge protection
•
Ethernet and power interface supervision
•
Clock distribution function
•
Ethernet link quality monitor function
•
Communication with Controller for provisioning and status report.
3.10.1.7 — Ethernet user interface
The following 4 Ethernet User Interfaces are available:
•
2 traffic 10/100/1000 Base-T Ethernet interfaces for data and service traffic via RJ45
connector.
N.B. For 100 Ethernet interface the standard is 100Base-Tx.
•
2 SFP ready to accept optical 1000Base-LX/SX SFP or Electrical 1000Base-T SFP.
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
MSS-1c to MPT-XP/XP-HQAM
MSS-1c to MPT-HC/HC-HQAM/9558HC
interconnection, and
Functional description
MSS-1c to MPT-
135