4.9.1.4.9.3.5 — E) Cross connection to user Ethernet port
Note: In case of the "One shot tributary configuration" is not fully displayed, check that
you have selected "classic window" setting, if you are using Windows Vista or Windows 7.
To configure a cross connection between an E1/T1 port and a user port:
•
First, enter the parameters as explained in the previous paragraphs, then
•
In column Service Profile: Select TDM2TDM or TDM2Eth. If TDM2TDM has been
selected the Ethernet user port must be connected to an Ethernet user port of another
MSS-c.
•
In column XCO to Port: Select a user port (user 1 to user 4) in the list
•
In column MAC Addr: Enter the External IWF MAC address which is used as
Destination Address in Ethernet frames built to carry TDM information in MPR
network