Before removing, first tighten the two screws gently, counting the number of turns, then
remove screws. Do not use too much force, or it will damage the air adjusting screw
head surface.
• Remove the main fuel injection nozzle and fuel injection needle seat.

FLOAT CHAMBER INSPECTION

Inspect the float for any damage and for fuel in the float. Inspect the float valve and float valve
seat for wear. If there is wear, it should be replaced.
Clear every fuel line and air line on the carburetor body with compressed air.

FLOAT CHAMBER INSTALLATION

• Install the main fuel injection nozzle and fuel injection needle seat.
• Install the air adjusting screw and choke adjusting screw, and turn them to the proper position ac-
cording to the noted number of turns while removing.
• Mount the float valve, the float, and the float pin.
• Tighten the float pin positioning screw.

FUEL LEVEL INSPECTION

• Measure the fuel level height.
• Inspect the float for any damage and inspect the float valve for excess wear.
• Confirm that the up and down movement of the float is normal.

CARBURETOR INSTALLATION

• Inspect the float for any damage and inspect the float valve for excess wear.
• Confirm that the up and down movement of the float is normal.
CARBURETOR INSTALLATION
• Reverse the removal procedure for installation.
• After installing, make sure all carburetor linkage and cables are in correct position, make sure
carburetor is in idle position,
Fuel level height
31
18.5mm