OIL SYSTEM INSPECTION AND REPLACEMENT

OIL REPLACEMENT
• Tighten the dipstick
• Remove the oil filter screen cap and the screen to let
the oil flow out.
• Inspect if there is any damage to the screen and O-ring, if so,
they should be replaced.
• Mount the oil filter screen and the screen covers and tighten
them. Supply the application-specific oil to the specific level.
Oil Level
Start the engine and run for several minutes in the idle position to make sure there is no oil leak-
ing. Stop the engine and inspect if the oil level is proper.

ROTARY OIL PUMP

The oil pump is the critical component of the lubrication system, so it should be inspected, maintained
periodically, and should be replaced as a unit when damaged seriously.

OIL PUMP REMOVAL

• Remove the flywheel of the magneto.
• Remove the stator coil and trigger winding.
• Remove the right crankcase cover bolts and remove the right
crankcase cover.
• Remove the gasket and dowel pins.
Disassembling
Replacing
0.90l
0.75l
25