Sirius 800 Series User Manual
Crosspoint Status
XpntCardNone
XpntCardRedundant
button
XpntCardMain button
Presence
Power
More button
Fault Fixed button
Free Failed Crosspoint
button
Table 10
5.4.2.1 Audio Crosspoint Failure
If an output module detects an error in the audio transport stream from the main audio
crosspoint module or if the stream is not present it will use the transport stream from the
redundant audio crosspoint module (if fitted). The Route Fail LED on the audio crosspoint
module with the failure will flash red, see section 10.5.1 for the location of the status LEDs.
Note:
A typical example of how the buttons will look is listed below, for button and parameter
locations see Figure 37 on page 69.
Iss 5 Rev 7
Screen Item
Sirius 800 Audio Crosspoint Matrix Status and Crosspoint Switching
For information on replacing a failed crosspoint card see section 10.5.5.
Fail Found indicator - Red
Fault Present indicator - Red
First Fail Detected - Failed Incoming Stream and/or Failed Outgoing Stream
will display the first failed stream(s)
XpntCardNone - Grey
XpntCardMain Yellow (indicates the main audio crosspoint has failed)
Description
Yellow = Main and redundant crosspoint modules working
correctly.
Grey = A fault has occurred or a crosspoint has been by-passed.
Touch the button to bypass the redundant crosspoint card.
Grey = Redundant crosspoint card is working correctly.
Yellow = Redundant crosspoint card has failed or been
bypassed.
Touch the button to bypass the main crosspoint card.
Grey = Main crosspoint card is working correctly
Yellow = Main crosspoint card has failed or been bypassed.
Green = Crosspoint module present
Red = Crosspoint module not present
Green = Crosspoint module is powered
Red = Crosspoint module is not powered
Displays the Modules screen, see section 5.2.2 for details.
Switches the routes back to the main crosspoint module once it
has been replaced.
Moves all of the routes from the failed crosspoint module to the
redundant crosspoint module. Also makes the redundant
crosspoint module the Clock Master allowing the failed crosspoint
module to be replaced. The "Route Active" LED on the failed
crosspoint module will go off.
The failed crosspoint card can be replaced without interrupting
any crosspoint routing once the routes have been switched to the
redundant crosspoint module, see section 10.5.5.
Page 71