5.4.1.1 Video Crosspoint Failure
When a video crosspoint routing failure is detected by the redundant crosspoint checking
algorithm the Nucleus router controller performs one of the following actions based on the
configuration in Workbench:
Note:
If one or more routes fail on a video crosspoint module this will be displayed on the Main or
Expansion Video Crosspoint Matrix Status screen. A typical example of how the buttons will
look is listed below (see Figure 35 on page 64 or Figure 36 on page 65 for button and
parameter locations):
Iss 5 Rev 7
Move the failed route to the redundant crosspoint (default when shipped).
Move all routes from the crosspoint module with the failure to the redundant
crosspoint module
Just notify the user and leave them to take appropriate action.
See section 10.6 for details on enabling/disabling video redundancy and section
10.7 for details on setting the redundancy action on crosspoint failure.
For information on replacing a failed crosspoint module see section 10.4.1.
Fail Found indicator - Red
Fault Present indicator - Red
First Failure Detected - Failed Source and Destinations will display the first
failed route
XpntCardNone - Grey
Failed Action: - text as configured in Workbench
Sirius 830
XpntCardMain830 Yellow (indicates the crosspoint has failed)
Sirius 840/850
XpntCardxxxToxxx_x - Yellow (where xxx is the failed crosspoint module)
Page 68
Redundant Crosspoint Control