Sam Sirius 840 User Manual page 70

Sirius 800 router range
Table of Contents

Advertisement

Sirius 800 Series User Manual
Clock Master
Failed Action
First Failure Detected (shown for Left and Right Audio Crosspoint Modules)
Failed Incoming Stream
Failed Outgoing Stream
Totals (shown for Left and Right Audio Crosspoint Modules)
Input Syncs OK
Input Sync Faults
Input Syncs in Use
Input Stream OK
Input Stream Faults
Output Stream OK
Output Stream Fault
Output Stream in Use
Table 10
Iss 5 Rev 7
Screen Item
Description
Displays the Audio Crosspoint module that is supplying the audio
system clock (Left or Right).
The Audio Crosspoint module either generates the audio system
clock (Clock Master) or uses the clock generated on the other
crosspoint (if fitted).
In normal operation the main crosspoint module generates the
audio system clock and the redundant crosspoint module is
slaved to that.
Displays the action that will be carried out by the router when a
crosspoint fails. This is configured in Workbench, see section
10.7 for configuration details.
Configuration options available are:
Displays the first incoming and first outgoing streams to fail on
each Audio Crosspoint module.
If all display zero and the Fail Found status is red then an entire
crosspoint module has failed. Check the Crosspoint Status of
crosspoint modules to determine which card has failed.
If both display zero and the Fail Found and Fail Present LEDs are
green then no fault has been found.
Displays the total number of successful input syncs for the audio
crosspoint module.
Displays the total number of failed input syncs for the audio
crosspoint module.
0 = No input sync faults (good)
Displays the total number of input syncs in use on the audio
crosspoint module.
Displays the total number of input streams without faults on the
audio crosspoint module.
Displays the total number of input stream faults for the audio
crosspoint module.
0 = No failed input streams (good)
Displays the total number of output streams without faults on the
audio crosspoint module.
Displays the total number of output stream faults for the audio
crosspoint module.
0 = No failed output streams (good)
Displays the total number of output streams in use on the audio
crosspoint module.
Sirius 800 Audio Crosspoint Matrix Status and Crosspoint Switching
Move the failed stream to the redundant crosspoint
(default when shipped).
Move all streams from the crosspoint module with the
failure to the redundant crosspoint module
Page 70
Redundant Crosspoint Control
Door PC 5.4
© 2017 SAM