Sam Sirius 840 User Manual page 293

Sirius 800 router range
Table of Contents

Advertisement

Sirius 800 Series User Manual
LED Color Function
Table 83
Iss 5 Rev 7
Remote
Error
(not 2453/
Red
2455/2457)
Green
Active
Control/Fan Interface Module LED Indication
Figure 188 Control/Fan Interface Module LEDs
Control/Fan Interface Module Compatibility
Detail
Error with messages from remote
Nucleus control module
Card is active
Page 293
Control/Fan Interface Module 15.1
Normal Working Status
Sirius 830 - not fitted
Sirius 840/850 - (no
expansion):
Off - Expansion not used.
Sirius 850 (expanded to
second frame):
Off - normal state,
Flashing - the command
message from the remote
router controller is corrupt
or hasn't been received.
This communications error
could be caused by a
hardware failure although
this is unlikely. Check that
the module is inserted
correctly and the four RJ45
connections between the
frames are fitted correctly
(see section 12.2).
If the "Remote Error" LED
is flashing at the same time
as the "Remote Command
OK" LED is flashing it
suggests a mismatch in the
configuration of the
Nucleus controller.
On Solid - working
correctly
© 2017 SAM