Sam Sirius 840 User Manual page 320

Sirius 800 router range
Table of Contents

Advertisement

Sirius 800 Series User Manual
C.2.3.1 5916 Input Module LED Information
Table 95 shows the LED color code on the 5916 input module, and Figure 199 shows the
input module.
LED Color Label
Table 99
Iss 5 Rev 7
Detail
Green
Power OK
Power to the module
Local
Receiving messages
Command
from local Nucleus
Yellow
OK
control module (the
Nucleus controller in
this frame)
Local Error Receiving CRC error
messages from local
Nucleus control module
(the Nucleus controller
in this frame)
Red
Remote
Receiving messages
Command
from remote Nucleus
OK
control module (the
Yellow
Nucleus controller in the
frame linked to this
frame)
Remote
Error with messages
Error
from remote Nucleus
control module (the
Nucleus controller in the
frame linked to this
frame)
Red
5916 Standard Video BNC/Fiber Input Module LED Information
Input Modules
Modules No Longer Supplied With New Systems C.2
Normal Working Status
On Solid - working correctly
Flashing - receiving information and
working correctly
Off - normal state
Flashing - the command message from
the router controller is corrupt or hasn't
been received.
This communications error could be
caused by a hardware failure or incorrect
insertion. Check that the module is
inserted correctly.
If the "Local Error" LED is flashing at the
same time as the "Local Command OK"
LED is flashing it suggests a mismatch in
the configuration of the Nucleus
controller. Check the controller
configuration.
Sirius 830/840/850 (no expansion):
Off - Expansion not used.
Sirius 850 (expanded to second frame):
Flashing - receiving information and
working correctly
Sirius 830/840/850 (no expansion):
Off - Expansion not used.
Sirius 850 (expanded to second frame):
Off - normal state,
Flashing - the command message from
the remote router controller is corrupt or
hasn't been received.
This communications error could be
caused by a hardware failure or incorrect
insertion. Check that the module is
inserted correctly and the four RJ45
connections between the frames are fitted
correctly (see section 12.2).
If the "Remote Error" LED is flashing at
the same time as the "Remote Command
OK" LED is flashing it suggests a
mismatch in the configuration of the
Nucleus controller. Check the controller
configuration.