Sam Sirius 840 User Manual page 269

Sirius 800 router range
Table of Contents

Advertisement

Sirius 800 Series User Manual
14.4.9 Enable/Disable RollCall on a Nucleus2 Controller Using the Online Editor
RollCall is enabled on the controller by default. If RollCall needs to be disabled then this is
done using the Workbench Generic Online Editor.
The RollCall Command Set Files must be present on the controller to connect using RollCall
(see the Sirius 800 Maintenance & Upgrade manual for details on installing these files if they
are not present).
Nucleus2 Router Control Module Navigate to:
ConfigurationItems | RollCall
Note:
Connect to the RollCall web applet by typing the controller IP address into the address bar of
your web browser. When the Nucleus2 web page is displayed click on the RollCall Control
tab and the RollCall web applet will start.
Iss 5 Rev 7
2464/2463 Nucleus2 Router Control Module
Enabled = - set to True to enable RollCall and False to disable RollCall. The other
settings are shown with their default values and they need not be changed unless
instructed to do so by SAM Support.
StartupDelay = 5
SharePort = 2050
BridgePort = 2600
BridgeRemoteAddress = 128.1.1.1
BridgeAutoConnect = False
Name = Router
Information1 = Info1
Information2 = Info2
NetNibbles = 1000
UseLongNames = False
Changes will not take effect until the controller has been reset.
If two Nucleus2 controllers are fitted in a router then the second one must also be
enabled for RollCall.
Page 269
Nucleus Router Control Modules 14.4
© 2017 SAM

Advertisement

Table of Contents
loading

Related Products for Sam Sirius 840

This manual is also suitable for:

Sirius 850Sirius 830

Table of Contents