Sirius 800 Series User Manual
Iss 5 Rev 7
1.
Touch the Free Failed Crosspoint button to move all of the routes from the failed video
crosspoint module to the redundant video crosspoint if Workbench has not been
configured to do this automatically.
2.
Check that the "Active" LED on the failed video crosspoint module is off and then
remove the failed video crosspoint module (see section 10.1.1 for the location of the
Active LED).
3.
Replace the failed video crosspoint module with a replacement working crosspoint
module.
4.
The replacement video crosspoint module is automatically tested and the Fault
Present indicator will change back to Green if the replacement is fully working.
5.
Touch the Fault Fixed button to move all of the routes from the redundant video
crosspoint module to the fixed video crosspoint module.
•
The Main or Expansion Video Crosspoint Matrix Status screen should now return to its
working state:
Sirius 830 - see Figure 35 on page 64 for button and parameter locations.
Sirius 840/850 - see Figure 36 on page 65 for button and parameter locations.
•
Fail Found indicator - Green
•
Fault Present indicator - Green
•
First Failure Detected - Failed Source and Destinations will both be reset to
Zero
•
XpntCardNone - Yellow
•
Sirius 830
•
XpntCardRedundant830 - Grey
•
XpntCardMain830 - Grey
•
Sirius 840/850
•
XpntCardOddToOdd_1 - Grey
•
XpntCardEvenToOdd_2 - Grey
•
XpntCardRedundant_R - Grey
•
XpntCardOddToEven_3 - Grey
•
XpntCardEvenToEven_4 - Grey
Video Crosspoint Failure
Page 165
Crosspoint Modules 10.4
© 2017 SAM