First Failure Detected
Failed Source
Failed Destination
Total Routes
Main Crosspoint
Redundant Crosspoint
Failed Action
Crosspoint Status
XpntCardNone
Fault Fixed button
Presence
Power
More button
Free Failed Crosspoint
button
Table 9
Iss 5 Rev 7
Screen Item
Description
The Failed Source and Failed Destination parameters show the
first failed route through the crosspoint that was detected.
If both display zero and the Fail Found status is red then an entire
crosspoint card has failed. Check the Crosspoint Status of each
crosspoint card to determine which card has failed.
If both display zero and the Fail Found and Fail Present LEDs are
green then no fault has been found.
Displays the total number of routes passing through the Main
crosspoint module(s).
Displays the total number of routes passing through the
Redundant crosspoint module.
Displays the action that will be carried out by the router when a
crosspoint fails. This is configured in Workbench, see section
10.7 for configuration details.
Configuration options available are:
Yellow = Main and redundant crosspoint modules working
correctly.
Grey = A fault has occurred or a crosspoint has been by-passed.
Switches the routes back to the main crosspoint module once it
has been replaced.
Green = Crosspoint module present
Red = Crosspoint module not present
Green = Crosspoint module is powered
Red = Crosspoint module is not powered
Displays the Modules screen, see section 5.2.2 for details.
Moves all of the routes from the failed crosspoint module to the
redundant crosspoint module allowing the failed crosspoint
module to be replaced. The "Active" LED on the failed crosspoint
module will go off.
The failed crosspoint card can be replaced without interrupting
any crosspoint routing once the routes have been switched to the
redundant crosspoint module, see section 10.4.1 for details.
Video Crosspoint Matrix Status Screen
Move the failed route to the redundant crosspoint
(default when shipped).
Move all routes from the crosspoint module with the
failure to the redundant crosspoint module
Notify the user and leave them to take appropriate action.