Konica Minolta Bizhub 4700P Service Manual page 181

Hide thumbs Also See for Bizhub 4700P:
Table of Contents

Advertisement

Removing a cable from the horizontal bottom contact connector
1. Place two fingers towards each end of the locking actuator, and then gently lift the actuator to the
unlocked position.
2. Slide the cable out of the connector.
Inserting a cable into the horizontal bottom contact connector
1. Check the actuator to verify it is in the open position.
2. Insert the cable into the ZIF connector with the contacts facing downward and away from the
locking actuator. The cable needs to be inserted below the actuator.
Note: Verify that the cable is installed squarely into the connector. If the cable is not squarely
installed, then intermittent failures could occur.
bizhub 4700P/bizhub 4000P Service Manual
- 180 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 4000p

Table of Contents