96Y Errors - Konica Minolta Bizhub 4700P Service Manual

Hide thumbs Also See for Bizhub 4700P:
Table of Contents

Advertisement

Error code
Description
959.37
Pensive command is invalid due to locked device
status
959.38
Incremental counter id(s) are invalid
959.39
Invalid NV address
959.40
Invalid Pensive command
Invalid firmware/controller board service check
Action
Update the firmware.
Note: Contact the next level of support for the correct firmware
level.
Does the error remain?

4.6.15 96y errors

96y error messages
Error
Description
code
960.xx
RAM Memory Error—RAM soldered on the card is bad
Replace the controller board.
961.xx
RAM Memory Error—optional DRAM is bad
964.xx
Download Emulation Cyclic Redundancy Check (CRC)
Error—checksum failure detected in the emulation
header or emulation file.
bizhub 4700P/bizhub 4000P Service Manual
- 124 -
Action
Go to
Invalid firmware/controller board
service
check.
Yes
No
Replace the
The problem is
controller board.
solved.
See
Controller
board
removal.
Action
Go to
Controller board
Go to
RAM memory error service
Go to
Download emulation cyclic
redundancy service
check.
removal.
check.