W&T 57630 Manual page 96

Web-io series 12+12 digital
Table of Contents

Advertisement

W&T
Server Password
A server password only needs to be entered if you want the Web-
IO to work as a box-to-box master or access an additional Web-IO
as a TCP client in server mode. See Box-to-Box section.
Inactive Timeout
Here you configure the timer used by the Web-IO to close the
connection after the time has expired. Enter the value in decimal
using 100ms increments. When there is an active network
connection the timer is reset once all the data have been
exchanged.
Example: The value 10 corresponds to one second. If no data
transfer is detected during this time, the Web-IO closes the
connection.
Entering no value means automatic connection closing is
deactivated.
Input Trigger
Check the inputs whose state change you want to use as triggers
for opening the TCP connection and sending data to the server
(important for event-triggered applications).
Interval
If you want to cyclically notify the server application of input state
changes, enter the interval here in (value will be multiplied with
100ms) .
Example: The value 300 corresponds to 30 seconds.
1
Please note that when using charged dial-up
connections, too short an interval can result in this
connection remaining open while charges continue to
accumulate!
Mode
Select here:
. Default - If you want access to the Web-IO to be password
protected.
96
TCP / UDP - Binary

Hide quick links: