W&T 57630 Manual page 108

Web-io series 12+12 digital
Table of Contents

Advertisement

W&T
The IO structure ClearCounter
The user program sends this structure to the Web-IO to reset
the counter state of a certain input counter to 0. Which input is
intended is sent in the variable counter_index
ClearCounter
(PC -> Web-IO)
IO-Structure ReadDiagnosis
If the Web-IO determines that there is a communications or
system error, the latter is listed on the HTML page diag and can
be read using the browser. Since error management via browser
for program-controlled applications is not always available, the
error status of the Web-IO can be queried using the structure
ReadDiagnosis
ReadDiagnosis
(PC -> Web-IO)
The Web-IO replies with a Diagnosis type structure.
IO-Structure Diagnosis
The Web-IO replies to the ReadDiagnosis structure with a Dia-
gnosis type structure.
Diagnosis
(PC <- Web-IO)
The variable diag_error_count returns how many various errors
are currently in the error memory. The Web-IO distinguishes a
total of up to 64 different error states, whereby each set bit of
the two variables diag_errrorbits0 and diag_errorbits1 stands
for an error type.
108
WORD
send_sequenz
WORD
rec_sequenz
WORD
struct_type
WORD
length
WORD
counter_index
WORD
send_sequenz
WORD
rec_sequenz
WORD
struct_type
WORD
length
WORD
send_sequenz
WORD
rec_sequenz
WORD
struct_type
WORD
length
LONG
word_anz
LONG
diag_error_count number of current errors
LONG
diag_errorbits0
LONG
diag_errorbits1
TCP / UDP - Binary
always 0
always 0
0x00B2
0x000A
Input 0..11 (23 for Web-IO 24)
always 0
always 0
0x00D1
0x0008
always 0
always 0
0x00D0
0x0018
in this release 3
binery error coding
binery error coding

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

57631