A reason for changing the factory default values for Local Port
and Slave Port might be for example a firewall that only allows
certain port accesses.
Server IP Addr:
Enter here the IP address of the Web-IO that you want to serve as
a slave.
Server Password:
Here you enter the Administrator password for the slave Web-
IO. If no password was assigned for the slave, leave this field
blank.
Inactive Timeout
This parameter has no function in Box-to-Box mode, since a
continuous connection is desired.
Input Trigger:
Activate here the inputs that will set the corresponding slave
outputs.
i
The Web-IO 12XDigital allows simultaneous access to
the inputs from various operation modes.
This means for example that inputs 0-5 control outputs 0-5 on the
slave Web-IO, but can also be read via HTTP at the same time.
Interval:
If no interval is entered, the state of the inputs is sent to the
outputs of the other Box-to-Box partner each time the state
changes. Entering an interval sends the state cyclically even if
there is no change.
1
If two locations are connected over a fee-based ISDN
line, you should not use an interval, since depending on
the timeout and interval the ISDN connection is never closed or is
very frequently reopened.
Application Mode
Select Box2Box Master
122
Box-to-Box