system error:
Serious hardware error. Try to restart the unit by disconnecting the
power supply. If the condition persists, please return the unit to
your dealer so that it can be checked by W&T.
Power-LED +Status-LED +Error-LED on
= Self-test error
The self-test performed by the Web-IO after each start or reset
could not be correctly finished, due for example to an incomplete
update of the firmware. In this condition the device is no longer
functional. Please return the unit to your dealer so that it can be
checked out by W&T.
1
If the Web-IO has no IP address or the address is 0.0.0.0,
the LEDs on error and system error will remain on after
a reset or new start! The LEDs will turn off only if an IP address
is assigned.