Extended Ambient Temperature Support

Use this option to enable the server to operate at higher ambient temperatures than are normally supported.
NOTE:
This option is only supported by specific hardware configurations. See your HPE server documentation before
enabling extended ambient temperature support. Improper system operation or damage to hardware
components can result from enabling these features in unsupported configurations.

Enabling or disabling higher ambient temperature support

Procedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > Advanced Options > Fan and Thermal Options > Extended Ambient Temperature Support
and press Enter.
2. Select a setting and press Enter.
a. Disabled
b. Enabled for 40c Ambient (ASHRAE 3)—Enables the server to operate in environments with ambient
temperatures up to 40 degrees Celsius.
c. Enabled for 45c Ambient (ASHRAE 4)—Enables the server to operate in environments with ambient
temperatures up to 45 degrees Celsius.
NOTE:
Not all servers support both 40c Ambient (ASHRAE 3) and 45c Ambient (ASHRAE 4).
3. Press F10.

Advanced System ROM Options

NMI Debug Button

PCI Bus Padding Options
Consistent Device Naming
Mixed Power Supply Reporting
Serial Number
Product ID
NMI Debug Button
Use this function to enable or disable debug functionality when the system experiences a software lock-up.
The button generates a Non-Maskable Interrupt to enable the use of the operating system debugger. When
enabled, pressing the NMI Debug Button on the system board during normal operation halts the system.