Appendix 2 Added And Changed Functions - Mitsubishi Electric FX5 User Manual

Melsec iq-f series, ethernet communication
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

Appendix 2
The functions added or changed with the CPU module and engineering tool, and the supported CPU modules' firmware
version and engineering tool software version are given below.
• The firmware version can be confirmed with module diagnosis (CPU diagnosis). Refer to the User's Manual (Hardware) for
the CPU module in use for details on diagnosing the module (CPU diagnosis).
• Refer to the GX Works3 Operating Manual for details on the software version.
Add/Change Function
The file transfer function is supported.
• Automatic detection of connected devices
• Communication setting reflection of Ethernet
device
• Sensor parameter read/write
IP filter function is supported.
MODBUS/TCP communication is supported.
Time setting function (SNTP client) is supported.
Web server function is supported.
During IP address duplication with the device on
the same network, the operation was improved
to output the information of the external device
with duplicated IP address.
*1 Supported with CPU module serial No. 16Y**** and above.
The following file transfer function (FTP server) controls are supported by "1.050" and above.
- Write/delete the file to/from the SD memory card
- Unlock/lock the remote password
- Reset the file password
- Change the setting value of the response monitoring timer
- Allow Online Change
*2 The remote password setting to the FTP server is supported by "1.050" and above.
*3 The response monitoring timer setting/Allow Online Change setting of the file transfer function, and the remote password setting to the
FTP server are supported by "1.035M" and above.
For the setting method of the remote password, refer to GX Works3 Operating Manual.
*4 Refer to the following.
iQ Sensor Solution Reference Manual
*5 Refer to the following.
MELSEC iQ-F FX5 User's Manual (MODBUS Communication)
APPX
170

Appendix 2 Added and Changed Functions

Added and Changed Functions
Supported CPU module
firmware version
*1*2
"1.040" and above
"1.040" and above
"1.050" and above
"1.060" and above
"1.060" and above
"1.060" and above
"1.061" and above
Supported engineering
Reference
tool software version
*3
"1.030G" and above
Page 101
*4
"1.030G" and above
"1.035M" and above
Page 130
*5
"1.040S" and above
"1.040S" and above
Page 113
"1.040S" and above
Page 116
Page 149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents