5.3

SLMP Commands

For details on the SLMP commands, refer to the MELSEC iQ-F FX5 User's Manual (SLMP).

Command list

The following commands can be executed with the SLMP function.
3E frames
Name
Command
Device Read
0401H
(Batch)
Device Write
1401H
(Batch)
Device Read
0403H
Random
5 SLMP FUNCTION
36
5.3 SLMP Commands
Sub-
Processing content
commands
0001H
This command reads data from a bit device or word device in units of
1 bit.
0000H
• This command reads data from bit devices in units of 16 bits.
• This command reads data from word devices in units of 1 word.
0081H
• This command reads data from the buffer memory in intelligent
function modules in units of 1 bit.
• This command reads data from devices indirectly specified by
index registers in units of 1 bit.
0080H
• This command reads data from the buffer memory in intelligent
function modules in units of 1 word.
• This command reads data from devices indirectly specified by
index registers in units of 1 word.
0083H
• This command reads data from the buffer memory in intelligent
function modules in units of 1 bit.
• This command reads data from devices indirectly specified by
index registers in units of 1 bit.
0082H
• This command reads data from the buffer memory in intelligent
function modules in units of 1 word.
• This command reads data from devices indirectly specified by
index registers in units of 1 word.
0001H
This command writes data to bit devices in units of 1 bit.
0000H
• This command writes data to bit devices in units of 16 bits.
• This command writes data to word devices in units of 1 word.
0081H
• This command writes data to the buffer memory in intelligent
function modules and SLMP-compatible devices in units of 1 bit.
• Bit devices, word devices, and buffer memory are indirectly
specified by index registers.
0080H
This command writes data to the buffer memory in intelligent function
modules and SLMP-compatible devices in units of 1 word (16 bits).
0083H
This command writes data to the buffer memory in intelligent function
modules and SLMP-compatible devices in units of 1 bit.
0082H
This command writes data to the buffer memory in intelligent function
modules and SLMP-compatible devices in units of 1 word (16 bits).
0000H
This command reads data from word devices in units of 1 word or 2
words by randomly specifying device numbers.
Number of points
processed per
communication
ASCII: 1792 points
BIN: 3584 points
ASCII: 480 words (7680 points)
BIN: 960 words (15360 points)
ASCII: 1792 points
BIN: 3584 points
ASCII: 480 words (7680 points)
BIN: 960 words (15360 points)
ASCII: 1792 points
BIN: 3584 points
ASCII: 480 words (7680 points)
BIN: 960 words (15360 points)
ASCII: 1792 points
BIN: 3584 points
ASCII: 480 words (7680 points)
BIN: 960 words (15360 points)
ASCII: 1792 points
BIN: 3584 points
ASCII: 480 words (7680 points)
BIN: 960 words (15360 points)
ASCII: 1972 points
BIN: 3584 points
ASCII: 480 words (7680 points)
BIN: 960 words (15360 points)
ASCII:
(Word access points + double
word access points)  2  192
BIN:
Word access points + double
word access points  192