Mitsubishi Electric FX5 User Manual page 104

Melsec iq-f series, ethernet communication
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

Item
Advanced
Password Setting
Setting
FTP Timer Settings
Allow Online Change
■Password Setting
• Current password
Enter the current password for login to the CPU module.
Default password (initial setting) is "FXCPU".
Although the default password can be used, it is recommended to change it to another password to prevent
unauthorized access.
• New password, confirm new password
Enter the new password in "New Password" and "Confirm New Password" when changing the password.
Set a password within 1 to 32 one-byte characters. Number, alphabet, special character (?,!&\%#*()[], etc.) can be used.
■FTP timer settings
• Command input monitoring timer
Set the monitoring time for the CPU module to monitor the command input time from the FTP client.
It is recommended to use the default value (900 s) for this timer value as much as possible.
When changing the setting value, determine the command input monitoring timer value upon consulting with the administrator
of the external device or system.
Set a value within the following range.
Unit
s
*1
ms
*1 Set in increments of 100 ms.
The FTP connection is disconnected if there is no command input from the FTP client side within the time of the command
input monitoring timer value after the FTP client login.
When restarting the file transfer, start over from the login operation again.
• Response Monitoring Timer
Set the monitoring time for a response from the CPU module after the CPU module receives the request data from the
external device.
It is recommended to use the default value (5 s) for this timer value as much as possible.
When changing the setting value, determine the response monitoring timer value upon consulting with the system
administrator.
Set a value within the following range.
Unit
s
*1
ms
*1 Set in increments of 100 ms.
8 FILE TRANSFER FUNCTION (FTP SERVER)
102
8.1 Data communication procedures
Description
Set the password to be used for file transfer request (login) from the
external device.
Set the command input monitoring timer and the response monitoring
timer used for the file transfer function (FTP server).
Select whether to enable data writing from the external device using
the file transfer function (FTP server) while the CPU module is in RUN
state.
Setting range
1 to 16383
100 to 16383000
Setting range
1 to 16383
100 to 16383000
Setting range
Page 102 Password Setting
Page 102 FTP timer settings
• Disable
• Enable
(Default: Disable)