Chapter 3 List Of Functions - Mitsubishi Electric FX5 User Manual

Melsec iq-f series, ethernet communication
Hide thumbs Also See for FX5:
Table of Contents

Advertisement

3
LIST OF FUNCTIONS
The following table shows the list of functions of the built-in Ethernet of the CPU module.
Function
Outline of system
Direct connection with
Built-in Ethernet of CPU module and MELSOFT product (GX Works3, etc.) are
MELSOFT
connected by single Ethernet cable without using a hub. Communication is done by
simply specifying the connection destination; you don't have to set the IP address.
MELSOFT connection
Communication with MELSOFT products (GX Works3, etc.) is done within LAN such as
company internal LAN.
Connected CPU search
Searches for built-in Ethernet (CPU module) connected with personal computer using
function
GX Works3 within the same hub. Acquires IP address by selecting from search results
list.
MELSOFT diagnosis function
Diagnoses built-in Ethernet of CPU module from GX Works3. (Ethernet diagnostics)
SLMP communication function
Reads and writes PLC data from other device.
Predefined protocol support
When the predefined protocol support function is used, data can be exchanged with the
function
external device.
Socket communication function
By using socket communication instructions, any data can be transferred from and to
the external devices connected through Ethernet using TCP or UDP.
MODBUS/TCP communication
By using sequence program, MODBUS devices of the external devices connected
through Ethernet can be read/written.
File Transfer Function
Using the dedicated FTP commands enables an external device to read out, write, and
(FTP server)
delete individual data file.
Time setting function (SNTP
Time information is collected from the time information server (SNTP server) connected
client)
on the LAN at the specified timing, and the CPU module's time is automatically set.
Web server function
CPU module diagnostics, device monitor, and device data read/write, etc., can be
performed from an Ethernet-connected device using a general-purpose Web browser.
IP filter function
This function identifies IP address of the access source and prevents access by
unauthorized IP addresses.
Remote password
Remote password setting can prevent unauthorized access from the outside and
enhance the security of the system.
IP address change function
This function is provided to change the IP address of the CPU module by setting the
desired IP address to special registers from a peripheral unit or another unit and turning
ON a special relay.
Automatic detection of
Detects devices supporting iQSS which are connected to the CPU module (built-in
connected devices
Ethernet port), and automatically displays them on "List of devices" and "Device map
area" using an engineering tool.
Communication setting
Reflects the communication settings (such as IP addresses) in devices supporting
reflection of Ethernet device
iQSS in "Device map area" which are connected over Ethernet.
Sensor parameter read/write
Reads/writes parameters from/to iQSS-compatible devices.
Reference
Page 18 Direct Connection with
Engineering Tool
Page 23 Connection via a hub
Page 27 Searching CPU Modules
on Network
Page 144 Ethernet diagnostics
Page 32 SLMP FUNCTION
Page 45 PREDEFINED
PROTOCOL SUPPORT
FUNCTION
Page 71 SOCKET
COMMUNICATION FUNCTION
MELSEC iQ-F FX5 User's
Manual (MODBUS
Communication)
Page 101 FILE TRANSFER
FUNCTION (FTP SERVER)
Page 113 TIME SETTING
FUNCTION (SNTP CLIENT)
Page 116 WEB SERVER
FUNCTION
Page 130 IP Filter Function
Page 133 Remote Password
Page 138 IP ADDRESS
CHANGE FUNCTION
iQ Sensor Solution Reference
Manual (SH-081133ENG)
3 LIST OF FUNCTIONS