Section 2 System Configuration

2-1-1 Expansion specifications

The table below shows the connectable expansion units.
Classification
Product name
Expansion right side
DIO expansion unit
unit
(with power supply)
DIO expansion unit
(without power supply)
AIO expansion unit
(without power supply)
Expansion power supply
unit
Healthy unit
(Terminating connector)
Communication unit
Expansion left side
unit
Function unit
AIO board
Front board
Communication board
Notes:
1) A healthy unit is used to detect a dropout of expansion right side units.
Be sure to mount a healthy unit to stop the SPF system with a fatal fault when an expansion right side unit is dropped.
Unless a healthy unit is mounted, a dropout of the expansion right side unit is not detected and the SPF system continues
operation in the state where the expansion right side unit is dropped.
Connect a healthy unit to the expansion connector (OUT) of the rightmost expansion right side unit after removing the
cover.
When mounting a healthy unit, register it in the system definition.
A healthy unit is excluded from the number of connectable expansion right side units (Max. 6).
2) A dropout of the communication unit/board and high-precision load cell unit is not detected.
Type
Specification
NA0E24R-34
Input 14 points, Ry output 10 points, DC power supply
NA0E24T-31
Input 14 points, Tr sink output 10 points, AC power supply
NA0E08R-3
Input 4 points, Ry output 4 points
Input 4 points, Tr sink output 4 points
NA0E08T-3
NA0E08X-3
Input 8 points
Tr sink output 8 points
NA0E08T-0
NA0E16R-0
Ry output 16 points
NA0E16T-0
Tr sink output 16 points
NA0AX06-MR
Analog input 6 channels
NA0AY02-MR
Analog output 2 channels
NA0AW06-MR
Analog input 4 channels, Analog output 2 channels
NA0AX02-TC
Thermocouple input 2 channels
NA0AX06-TC
Thermocouple input 6 channels
NA0AX16-TC
Thermocouple input 16 channels
NA0AX06-PT
Resistance thermometer element input 6 channels
NA0F-LC1
Load cell unit, 1 channel
NA0S-2
Input 100 to 240V AC
NA0S-4
Input 24V DC
Unit for detecting a dropout/fault of expansion right side
NA8P-HE
units
NA0LA-RS2
RS-232c: 2 ports
NA0LA-RS5
RS-485: 2 ports
NA0LA-ET1
Ethernet 1 channel
NA0FA-LC1
High-precision load cell unit, 1 channel (Note 2)
NA3AY02-MR
Analog output 2 channels
NA3AW03-MR
Analog input 2 channels, Analog output 1 channel
NA3LA-RS1
RS-232C: 1 port, RS-485: 1 port
NA3LA-ET1
Ethernet 1 channel
2-2
(Note 1)
(Note 2)
(Note 2)
(Note 2)
(Note 2)
(Note 2)