6.3.3.6

Working with analog inputs

The following reference contains more information about analog inputs:
● /IH1/
● /GH1/
6.3.3.7

Commissioning

Information about commissioning can be found in the
Hardware Installation Manual.
6.3.4

Technical Specifications

Power supply of digital outputs
Table 6- 10
Characteristic
Power supply
Response time
SIMOTION D4x5-2
Manual, 02/2012
SINAMICS S120
Commissioning Manual.
SINAMICS S120
Control Units and Additional System Components Manual
Terminal block X424
Value/Range
Voltage: 24 VDC (20.4 V – 28.8 V)
Current via the option slot of the D4x5-2 (without digital outputs): 0.05 A
Max. power consumption: 4 A
Max. power consumption per digital output: 0.5 A
Power loss: < 3 W
The response time of digital inputs/outputs and analog inputs/outputs
depends on the evaluation on the control unit (see function diagram).
References: SINAMICS S120/S150 List Manual, Chapter "Function
diagrams"
Supplementary system components
6.3 TB30 terminal board