Facing And Finishing Requirements - kozy heat CALLAWAY 50 Installation And Operation Manual

Direct vent gas fireplace
Hide thumbs Also See for CALLAWAY 50:
Table of Contents

Advertisement

4.2 Facing and Finishing Requirements

WARNING: Maintain all minimum clearances to combustibles from the
appliance and vent system.
4.2.1 Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be
maintained.
Combustible Mantel Projections - Minimum Vertical and
Maximum Horizontal: 18 in (457 mm) is the minimum vertical
clearance from the top of the finishing edge to 6 in (152 mm)
maximum depth of a combustible mantel. Combustible mantels
at the minimum vertical clearance may be 0 in (0 mm) to 6 in
(mm) depth with minimum vertical clearance 18 in (457 mm).
Non-combustible Mantel Projections - Minimum Vertical and
Maximum Horizontal: A minimum vertical clearance of 6 in (152
mm) above the finishing edge to a maximum 6 in (152 mm)
depth of a non-combustible mantel. Follow projection 1 in (25
mm) up for every 1 in (25 mm) deeper.
4.2.2 Facing Requirements
Non-combustible material is required at the top and sides of the
fireplace. This fireplace is designed to accommodate non-combustible
facing material up to ½ in (13mm) thick.
EACH SQUARE REPRESENTS
OF MANTEL PROJECTION
27
(698mm)
Figure 4.2, Mantel Requirements
#CLW-50 R.1 March 2018
1" (25mm)
12" (305mm)
9" (229mm)
6" (152mm)
¾
"
STEEL
½
TRIM
"
FRAMING
½
21
"
(545mm)
18"
(457mm)
FINISHING EDGE
48"
(1219mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Install facing material up to the finishing edge that surrounds
the glass frame assembly. Do not apply any material beyond this
point. The glass frame assembly must be removable.
Do not secure material to the lower cover panel using screws.
This may damage control system components. To secure material
to this area, use a silicone sealant that has a 300°F (149°C)
continuous exposure rating.
It is acceptable to pre-drill holes and to use self-tapping screws
prior to attach the non-combustible material to the top and
sides of the fireplace face. Do not use excessively long screws.
4.2.3 Finishing Recommendations
NOTE: The surface area above the appliance may be affected by high
temperatures emitted from this appliance. To help avoid or reduce the
possibility of the sheetrock to crack, Hussong Mfg. recommends the
following methods:
Ensure the non-combustible material and sheetrock is dry and
dust free.
For taping and mudding seams, we recommend heat resilient
tape, mesh and joint compounds, such as Durabond. Mud must
be cured as per manufacturer's recommendations.
For a painted surface, use a high quality acrylic latex primer
and finish coat. Avoid flat or light-colored paints to prevent
discoloring.
22"
(559mm)
48"
(1219mm)
COMBUSTIBLE FLOORING
FACING AND FINISHING 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clw-50

Table of Contents