kozy heat Callaway 50 Series Installation And Operation Manual

kozy heat Callaway 50 Series Installation And Operation Manual

Direct vent gas linear fireplace
Table of Contents

Advertisement

HUSSONG MANUFACTURING CO., INC.
C A L L A W A Y
Model #CLW-50
Direct Vent Gas Linear Fireplace
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
ͷ Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
ͷ Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
Hussong Mfg. Co., Inc. • CLW-50
5 0
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATION AND
OPERATION MANUAL
This
appliance
an
aftermarket,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
DANGER
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
Report No: 19-477 • Rev. 4, November 2019
may
be
installed
permanently
located,
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
in

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Callaway 50 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for kozy heat Callaway 50 Series

  • Page 1 INSTALLATION AND OPERATION MANUAL HUSSONG MANUFACTURING CO., INC. C A L L A W A Y Model #CLW-50 Direct Vent Gas Linear Fireplace English and French installation manuals are available through your local dealer. Visit our website www.kozyheat.com. Les manuels d’installation en français et en anglais sont disponibles chez votre détaillant local.
  • Page 3 Please retain this owner’s manual for future reference. CON GRAT ULAT I ON S! We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and materials, and assembled by trained craftsmen who take pride in their work.
  • Page 5: Table Of Contents

    7.1 Approved Vent Systems ................40 14.0 REPLACEMENT PARTS LIST..........67 7.2 Venting Requirements ................40 7.3 Use of Elbows ....................40 LIMITED LIFETIME WARRANTY ............ 68 #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TABLE OF CONTENTS 5...
  • Page 7: Introduction

    Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7...
  • Page 8: Specifications

    Verify the household breaker is shut off prior to working on any electrical lines. • The AC power supply to this appliance must be hot at all times and shall not have a switch installed in it. 8 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 9: Appliance Dimensions

    Power Vent wire harness hole (1512mm) (140mm) (68mm) (see KPV manual for more information) Power Vent wire harness hole (see KPV manual for more information) Figure 2.1, CLW-50 Dimensions #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces SPECIFICATIONS 9...
  • Page 10: Barrier Dimensions

    Rectangle Surround (1 piece) Rectangle Surround (4 piece) CW50-RS CW50-RS4 ⁄ ” 65” (1426mm) (1651mm) ¼ ⁄ ” ” (539mm) (573mm) Gallery Surround Forged Surround CW50-GS CW50-FS 10 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 11: Framing

    1510A), please reference the manual included with your kit before completing all fireplace framing and other installation considerations. Please read the instructions in this manual carefully for your specific installation. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 11...
  • Page 12: Stand-Off Assembly And Installation

    Remove and save (4) screws securing the stand-off brackets on top of the fireplace. Form each stand-off bracket by bending at perforations, as shown. Figure 3.1, Stand-off Assembly and Installation 12 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 13: Nailing Flange Assembly And Installation

    Nailing ange as shipped TOP VIEW FRONT VIEW Framing stud 2½” Stand-o ange Nailing ange (64mm) Clearance Framing stud Nailing ange Figure 3.2, Nailing Flange Installation #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 13...
  • Page 14: Standard Installation

    (1638mm) Typical Corner Installation ⁄ ” (657mm) ⁄ ” (1357mm) ⁄ ” ½ ” (2714mm) (1638mm) ⁄ ” 3” (1919mm) (76mm) Figure 3.3, Clearance to Combustibles 14 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 15 TV Recess Construction ½ ” (1130mm) 48” (1219mm) ½ ” ½ (1130mm) ” 48” (1638mm) (1219mm) ½ ” (1638mm) 22” (559mm) 22” (559mm) Figure 3.4, Framing Dimensions #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 15...
  • Page 16: Natural Draft Vent Termination Rough Framing

    Attic insulation shields may be insulated using unfaced insulation products listed as non-combustible per ASTM E 136. Rough framing for horizontal terminations are on the following page. 16 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 17 3.6.2.1 Wall Pass Through Information and Framing 12” (305mm) of travel. Kozy Heat’s #800-WPT series, or wall thimble products that comply NOTE: Elbows listed with approved vent systems for this appliance vary with the required 3” (76mm) top clearance to combustibles, must in vertical length.
  • Page 18: Outdoor Covered Fireplace Installation

    The width of the overhang to EACH side of the replace (C) must be 5 ft or greater. Figure 3.6, Outdoor Covered Fireplace Install - 1 18 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 19 MEMBRANE IS NOT TO BE INTERRUPTED BY FIREPLACE INSTALLATION MINIMUM WEATHERPROOF OVERHANG IN FRONT AND SIDES OUTSIDE INSIDE FREE STANDING STRUCTURE (WEATHERPROOF ENCLOSURE) Figure 3.7, Outdoor Covered Installation Guide - 2 #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 19...
  • Page 20: Heat Distribution Cover Plates

    Remove (1) square cover plate per kit, up to (2) kits may be used See heat transfer kit manuals for more information Figure 3.8, Heat Transfer Kit Cover Plate Removal 20 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 21: Vented Cavity And Kzk Installation

    Convection air ow with ba e in place Figure 3.10, Air Flow Inside Appliance with Convection Baffle Removed Figure 3.11, Convection Baffle Removal #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 21...
  • Page 22 Mantel 6” (152mm) deep from fireplace finishing edge 0” Mantel 6” (152mm) deep from fireplace enclosure floor 26-1/2” 673mm Minimum height of fireplace enclosure 76” 1930mm Minimum width of fireplace enclosure 64-1/2” 1638mm 22 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 23 (1130mm) 22” 76” (559mm) ½ ” (1930mm) (1638mm) ½ ” 22” (1130mm) (559mm) Figure 3.13, KZK, Vented Cavity, and HTK Framing Dimensions with TV Recess Construction #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 23...
  • Page 24 * must maintain 2½” clearance for full length of crown molding/trim projection ½ ” (1359mm) Figure 3.17, Front Vented Cavity Crown Molding Installation Figure 3.14, Front Vented Cavity Installation 24 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 25 76” MIN 8” Air discharge overhang 53½” MIN 4” MIN Air discharge opening 6” MAX 61½” MIN Figure 3.18, Front Vented Cavity Alternative Installation with Overhang #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 25...
  • Page 26 Top Vented Cavity Framing ½ ” (38mm) ½ ” (38mm) ½ ” (38mm) Figure 3.19, Top Vented Cavity Installation 26 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 27 6” MAX 76” MIN 8” Air discharge overhang Air discharge opening 6” MAX 8” Width of Fireplace Chamber Figure 3.21, Top Vented Cavity Alternative Installation with Overhang #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 27...
  • Page 28: Facing And Finishing

    1/2" (13mm) in the allowed areas. See Figure 4.3 and Figure 4.4 on page 30. 28 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 29 (458mm) ½ ” ½ ” (1131mm) (1359mm) ½ ” ¾ ” (140mm) (425mm) ¾ ” (248mm) ½ ” (1638mm) Figure 4.2, Framed Opening Clearances #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 29...
  • Page 30 No Screws Allowed ¾ 13” ” 13” ¾ ” (330mm) (95mm) (330mm) (95mm) Figure 4.4, Minimum Non-Combustible Finishing Dimensions Screw Locations for all installations 30 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 31: Cw50-Sck Optional Skim Coat Kit

    30 for maintaining required areas. Figure 4.8, Installed Panels and Non-Combustible Material Figure 4.5, Hand Bend Tab Figure 4.6, Aligned Corners #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 31...
  • Page 32: Masonry Finishing Guidelines For Optional Surrounds

    CW50-RS4 2-5/8" (66mm) 2-5/8" (66mm) CW50-GS 6" (152mm) 2-1/2" (64mm) CW50-FS 3-1/8" (79mm) 3-1/8" (79mm) Figure 4.9, Guidelines for Masonry Finishing with Optional Surrounds 32 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 33: Barrier And Optional Surround Installation

    To remove safety screen: lift the screen up and out of slots. (2) TRUSS HEAD SCREWS - LEFT SIDE MOUTNING NUTS SAFETY BARRIER SCREEN #CW50-ES Figure 4.11, Surround Installation Figure 4.10, Safety Screen Installation #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 33...
  • Page 34: Vented Cavity And Kzk Facing And Finishing Requirements

    The glass frame assembly must be removable. • Material may be attached to the bottom front cover panel using a silicone sealant that has a 300°F (149°C) continuous exposure rating. 34 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 35 9” (229mm) ¾ ” (248mm) 12” (305mm) Fireplace Enclosure Floor Figure 4.12, Hearth and Mantel Clearances for No Surround (shown with a KZK installed) #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 35...
  • Page 36 Steel Framing Finishing Edge Finishing Edge Fireplace Enclosure oor Figure 4.13, Combustible Wall Finish up to 1" (25mm) thick 36 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 37: Gas Line Connection

    Natural Gas 5” WC (1.25 kPa) 10.5” WC (2.62 kPa) 7” WC 1.74 kPa recommended Propane 12” WC (2.99 kPa) 13” WC (3.24 kPa) recommended #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces GAS LINE CONNECTION 37...
  • Page 38: Termination Locations

    Over 12/12 to 14/12 1.52 Over 14/12 to 16/12 1.83 Over 16/12 to 18/12 2.13 Over 18/12 to 20/12 2.27 Over 20/12 to 21/12 2.44 38 TERMINATION LOCATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 39: Minimum Termination Clearances

    VINYL SOFFIT, VINYL CEILING, AND VINYL OVERHANG DISCLAIMER: Clearances to heat resistant material (i.e. wood, metal). This does not include vinyl. Hussong Manufacturing Co., Inc. will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings, or vinyl ventilated/unventilated soffits. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TERMINATION LOCATIONS 39...
  • Page 40: Venting

    (203mm) air intake co-axial vent pipe system. • For each additional 90° elbow used after the first elbow, 3’ (91.4 This appliance is approved for use for Kozy Heat Power Venting #KPV cm) must be subtracted from maximum venting allowed. (sold separately).
  • Page 41: Natural Draft Vent Installation

    45° horizontal elbow + 6” (152mm) minimum horizontal length / 24” (609mm) maximum horizontal length + termination cap 50’ (15.24m) 3’ (914mm) 24” (610mm) 6” (152mm) #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces VENTING 41...
  • Page 42 6” (152mm) 48” 6” (1219mm) (152mm) 12” (305mm) vent pipe 20’ 48” (7.32m) (1219mm) 6” 6” (152mm) (152mm) 24” (610mm) vent pipe 24” (610mm) vent pipe 42 VENTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 43 25’ (7.6m) maximum vertical rise + 25’ (7.6m) maximum horizontal run = 50’ (15.2m) of total length • Maximum of (5) 90° elbows. Figure 7.2, Combination Venting #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces VENTING 43...
  • Page 44: Class A Chimney/Masonry Chimney Conversion

    45° horizontal elbow +retro connector + 10’ (3.05m) minimum length of 4” aluminum flexible pipe / 50’ (15.24m) maximum length of 4” aluminum flexible pipe + top adapter + termination 44 VENTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 45: Coaxial To Co-Linear Chimney Conversion

    +10’ (3.05m) minimum length of 3” x 3” aluminum flexible pipe / 50’ (15.24m) maximum length of 3” x 3” aluminum flexible pipe + termination cap #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces VENTING 45...
  • Page 46: Horizontal Heat Shield Installation

    (provided). The 1” (25mm) vent stand-off tab will rest on top of the vent pipe. Vent Stand-o Tab Attachment Screws Figure 7.3, Installed Heat Shield Assembly 46 VENTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 47: 800-Wpt Series Installation Instructions

    1-1/2” (38mm). An extension will be needed if going through a thicker wall than 6-1/2” (165mm). Refer to BDM vent If installing Kozy Heat #800 Series Flexible Vent System with either manufacturer if wall extension is necessary.
  • Page 48: Fireplace Setup

    Burner media installation - install an even layer across the whole burner (shaded area) Perimeter media installation - install an even layer across the front and rear perimeter (shaded area) Figure 8.1, Media Installation 48 FIREPLACE SETUP Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 49: Control Board Removal And Installation

    11. Turn the manual valve counterclockwise to the ON position. 12. Reconnect electrical power. 13. Verify proper media placement, operation of fireplace, and any electrical components. Figure 8.2, Control Board Removal and Installation #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FIREPLACE SETUP 49...
  • Page 50: Electrical Information

    National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. Figure 9.1, Wiring Schematics 50 ELECTRICAL INFORMATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 51: 600-Tlk Top Light Kit

    (4) sheet metal screws previously removed and (4) sheet metal screws (included with this kit). Locate the wiring previously fed through the light kit holes below the firebox. Reference Figure 9.2 for proper wiring. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ELECTRICAL INFORMATION...
  • Page 52 YELLOW FEMALE CONNECTORS RED MALE CONNECTORS BLUE FEMALE CONNECTORS RED MALE CONNECTORS (from control module) Figure 9.2, Wiring Schematic for 600-TLK 52 ELECTRICAL INFORMATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 53: Sl42-028 Optional Fan Kit

    Plug the fan cord into the receptacle on the IFC control module. 10. Reinstall the glass frame assembly, access cover and safety barrier. Figure 9.4, Steps 5 through 9 Figure 9.3, Steps 3 and 4 #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ELECTRICAL INFORMATION...
  • Page 54: Operating Instructions

    This fireplace may produce noises of varying degree as it heats and cools due to metal expansion and contraction. This is normal, and does not affect the performance or longevity of the fireplace. 54 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 55: Setup Proflame

    Turn the main burner OFF by setting the ON/OFF switch in the OFF position. The pilot will remain lit even if burner is turned off, provided CPI mode is turned on. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS 55...
  • Page 56: Ifc Module Ignition Sequence

    Red LED Indicator will blink (3) times in intervals. • Verify gas is turned on. • Verify sensor is not shorted. • Follow Section 10.2 Initialize the Control System. 56 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 57: Remote Control Operation

    LCD screen. Simultaneously press the mode key and the up arrow key to activate or deactivate this function. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS 57...
  • Page 58 ‘ON’ or ‘OFF’ . Verify all (3) AAA batteries are installed in the remote control. Remove (1) AAA battery. 58 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 59 A single ‘beep’ will confirm reception of the command. 10.8.9.1 Deactivate Light Kit Modulation Verify all (3) AAA batteries are installed in the remote control battery bay. Remove (1) AAA battery. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS 59...
  • Page 60: Adjustment

    (A) to verify the tap is completely sealed. Manometer should read no pressure. (A) INLET PRESSURE (B) MANIFOLD PRESSURE TAP Figure 11.1, Pressure Check Taps 60 ADJUSTMENT Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 61: Burner Flame Adjustments

    Venturi settings(s) closed too far. Open venturi(s) slightly OR gas pressure too high - check manometer settings BURNER VENTURI Figure 11.3, Flame Appearance and Characteristics Figure 11.2, Burner Venturi #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ADJUSTMENT 61...
  • Page 62 (127mm) exhaust pipe. Make necessary modifications to achieve desired flame appearance. Insert restrictor plate into the 5” (127mm) exhaust pipe with the tabs pointing towards the ceiling. Reinstall all components previously removed. 62 ADJUSTMENT Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 63: Troubleshooting

    Remote control not working Replace batteries. properly No call for heat Verify remote control is powered ON and thermostat operation is turned OFF. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TROUBLESHOOTING 63...
  • Page 64 Reprogram remote control to IFC module. remote control and IFC module A maximum number of failed Reset IFC module. ignitions or flame restorations has been reached 64 TROUBLESHOOTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 65: Maintenance

    Qualified Service Person Performed by: Annually Frequency: Action: • Examination of the vent system is required. • The flow of combustion and ventilation air must not be obstructed. #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces MAINTENANCE 65...
  • Page 66: Burner And Pilot System

    Figure 13.2, Pilot and Burner Correct Flame Appearance safety system. It must de-energize the safety shutoff in no more than (30) seconds. Burner Ports BURNER ORIFICE Figure 13.1, Burner System 66 MAINTENANCE Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CLW-50 R.4 November 2019...
  • Page 67: Replacement Parts List

    700-203 Vent Heat Shield Assembly CW50-HHSS Steel Framing CW50-SHD Hussong Manufacturing Co., Inc. P.O. Box 577 204 Industrial Park Drive Lakefield, MN 56150-0577 CLW-50 #CLW-50 R.4 November 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces REPLACEMENT PARTS LIST 67...
  • Page 68: Limited Lifetime Warranty

    • All parts and material except the items listed in the 30 day Kozy Heat gas appliance from the date of purchase to the original warranty and any exclusions or limitations that may apply. purchaser, that it is free of defects in materials and workmanship at *Hussong Mfg.

Table of Contents