3.
While reinserting the battery, push and hold the thermostat key.
The temperature bulb graphic will not be displayed on the LCD
screen.
4.
To reactivate remote thermostat operation, follow the same key
sequence procedure above. The temperature bulb graphic will
reappear on the LCD screen.
10.8.8 Fan Speed Control (optional)
Fan speed can be adjusted through (6) speeds. To activate this
function,
1.
Press the mode key to index to the fan control icon.
2.
Press the up or down arrow keys to turn on, off, or to adjust fan
speed.
Fan(s) have a (5) minute delay time when the
Thermostat mode:
fireplace is let. This allows time for heat to build in fireplace before
fan operation. The fan will continue to operate for approximately (12)
minutes after the fireplace has been turned off.
Fan(s) will operate at previous setting. There is no delay
Manual mode:
in start up or stop time.
10.8.9 Accent Light Kit (if applicable)
The light intensity can be adjusted through (6) levels.
1.
Press the mode key to index to the light icon.
2.
Press the up or down arrow keys to adjust the intensity level.
3.
A single 'beep' will confirm reception of the command.
10.8.9.1 Deactivate Light Kit Modulation
1.
Verify all (3) AAA batteries are installed in the remote control
battery bay.
2.
Remove (1) AAA battery.
#CLW-50 R.1 March 2018
3.
Press and hold the on/off key and the mode key at the same
time.
4.
Reinsert (1) AAA battery.
While still holding the on/off key, let go of ONLY the mode key.
5.
6.
Index over to the bulb graphic on the LCD screen to edit. Use the
up or down arrow key to choose 'SET' or 'CLR' .
10.8.10 Remote Control Low Battery Detection
Remote control battery lifespan depends on various factors including
battery quality, number of ignitions, changes to room thermostat set
point, etcetera.
When the remote control battery are low, a battery icon will
appear on the LCD display before all battery power is lost.
When the batteries are replaced, this icon will disappear.