Clearances To Combustibles - kozy heat CALLAWAY 50 Installation And Operation Manual

Direct vent gas fireplace
Hide thumbs Also See for CALLAWAY 50:
Table of Contents

Advertisement

3.3 Clearances to Combustibles

From appliance top stand-off brackets
From appliance left and right stand-off brackets
From appliance back stand-off brackets
From appliance corners
From appliance front
Appliance sides to adjacent sidewall
Fireplace finishing edge to 3/4 in (19 mm) trim
Mantel 6 in (152 mm) deep from fireplace finishing edge
Mantel 6 in (152 mm) deep from fireplace enclosure floor
Minimum height of fireplace enclosure
TYPICAL VERTICAL INSTALLATION
3"
(76mm)
22"
(559mm)
STEEL FRAMING REQUIRED
Figure 3.2, Clearance to Combustibles
12 FRAMING
Table 3.1, Minimum Appliance Clearances to Combustible Material
STEEL FRAMING REQUIRED
STEEL FRAMING REQUIRED
½
64
"
(1638mm)
TYPICAL CORNER INSTALLATION
106
"
(2714mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
22"
(559mm)
25
"
(657mm)
½
64
"
(1638mm)
3-1/2 in
0 in
0 in
3 in
36 in
3 in
18 in
21-1/2 in
48 in
48 in
TYPICAL HORIZONTAL INSTALLATION
3"
(76mm)
STEEL FRAMING REQUIRED
STEEL FRAMING REQUIRED
STEEL FRAMING REQUIRED
½
64
"
(1638mm)
53
"
(1357mm)
75
"
3"
(1919mm)
(76mm)
#CLW-50 R.1 March 2018
89 mm
0 mm
0 mm
76 mm
914 mm
76 mm
457 mm
545 mm
1219 mm
1219 mm