3.0 FACING AND FINISHING

3.1 Facing and Finishing Requirements

3.1.1 Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be
maintained.
Combustible Mantel Projections: As referenced in Figure 3.1,
the 2" (51mm) mantel can start at 2-3/4" (69mm) above the
top of the viewing opening. Mantel projections can increase 2"
(51mm) of depth for every 1" (25mm) of height starting at the 2"
(51mm) mantel.
3.1.2 Finishing Requirements
This appliance is designed to accommodate finishing material up
to 5/8" (16mm) thick.
5"
(127mm)
Figure 3.1, Mantel Clearances
#OSO-29 #OSO-34 R.1 November 2020
All manuals and user guides at all-guides.com
Each square represents
1" (25mm)
of mantel projection
10" (254mm)
8" (203mm)
6" (152mm)
4"
2"
(102mm)
(51mm)
Top of viewing opening
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
¾
2
"
(69mm)
Nominal 2" x 4" framing used in framing
FACING AND FINISHING 15