8.0 FACING AND FINISHING

8.1 Facing and Finishing Requirements

IMPORTANT: Adequate accessibility clearances for servicing and
proper operation must be maintained.
8.1.1 Adjacent Sidewall Requirements
The adjacent sidewall minimum clearance is 6" (152mm) from
the appliance sides (Fig 8.1).
8.1.2 Clearance to Ceiling
As shown in Figures 8.1 and 8.4, the minimum clearance from the
fireplace enclosure floor to the ceiling is 55" (1.04m).
8.1.3 Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be
maintained.
Combustible Mantel Projections - As referenced in Figure 8.2, the
9" (229mm) mantel can start at 16" (254mm) above the top of the
appliance. Mantel projections can increase 1" (25mm) of depth
for every 1" (25mm) of height starting at the 9" (229mm) mantel.
CK29-LMK Mantel Projections (FOR USE ONLY with safety barriers
#CK29-RSF & #CK29-PSF) - As referenced in Figure 8.4, the 6"
(152mm) mantel can start at 11" (279mm) above the top of
the appliance only when the low mantel kit is installed. Mantel
projections can increase 1" (25mm) of depth for every 1" (25mm)
of height starting at the 6" (152mm) mantel
22 FACING AND FINISHING
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#CSK-29-G R.9 August 2020