Changing The Configuration Data - Omron G9SP-N20S Operation Manuals

G9sp series g9sp-n series safety controller
Hide thumbs Also See for G9SP-N20S:
Table of Contents

Advertisement

Changing the Configuration Data

9-4

Changing the Configuration Data

Procedure for Changing the Configuration
1,2,3...
This section describes how to change the G9SP-series Controller configura-
tion data after the configuration has been downloaded or after operation has
been started.
To change the G9SP-series Controller configuration data, first carefully check
system safety and then unlock the configuration data. The procedure for
changing the configuration is as follows:
1. Check the system safety.
2. Change the G9SP-series Controller's operating mode from RUN to IDLE.
3. Unlock the G9SP-series Controller configuration data.
4. Download the configuration data to the G9SP-series Controller.
5. Verify the configuration data.
6. Change the G9SP-series Controller's operating mode from IDLE to RUN.
7. Perform safety validation testing (user testing).
8. Lock the configuration data.
Precautions for Safe Use
After changing the G9SP-series Controller's configuration data, confirm that
the safety functions are functioning properly before starting operation.
Section 9-4
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

G9sp-n10dG9sp-n10sG9sp series

Table of Contents