Monitoring Programs
10-2 Monitoring Programs
10-2-1 Program Monitor
Procedure
1,2,3...
Window Description
152
The G9SP Configurator can be used to graphically monitor program execution
in the G9SP-series Controller.
1. Go online and then click the Program Monitor Icon
2. The background of the Program Window will change to light blue and "On-
line Monitor" will be displayed at the lower right of the window.
Background: Light green
When a value is "ON,
" changes to green.
Additional Information
• The display of function blocks with errors in the Output Window can be
updated by selecting Search Failed Function Blocks from the Online
Debug Menu.
• The program and configuration data, such as the system settings, cannot
be changed while monitoring the program. End program monitoring to
change them.
Section 10-2
.
If an error occurs, the function block
changes to red.
Displays function blocks where errors have
occurred. Double-click a line to jump to the
relevant page.