Section 6 – Scheduling Options

Bank Safe and Vault

The Bank Safe or Vault should be limited to its own partition where only a Master or Manager code would be allowed to
operate (see Section 2 of this Manual - Partitioning). If regular users are enabled there is a way to disable their access
(see below):
1. Enter Scheduling Mode by entering Installer Code + [#] + [80].
2. Select Time Windows.
3. Create Time Window 01 as -6:00am-10:00am.
4. Create Time Window 02 as 9:30pm-10:00pm, enter 00 + ∗ to exit Time Windows.
5. Do not Quit Menu Mode, go to O/C Schedules.
6. Enter Vault Partition #.
7. Assign Window 01 as the OP window and Window 02 as the Cl Window for Monday thru Saturday. Exit Program
mode.

Vault Partition

1. Program 2∗ ∗ ∗ ∗ 05 = 00, Auto-Arm Delay (partition-specific) Arm at 10pm.
2. Program 2∗ ∗ ∗ ∗ 06 = 00, Auto-Arm Warning Period (partition-specific) No Warning Period.
3. Program 2∗ ∗ ∗ ∗ 07 = 00, Auto-Disarm Delay (partition-specific) Disarm at 6am.
4. Program 2∗ ∗ ∗ ∗ 08 = 1, Force Arm (partition-specific) Enable.
5. Program 2∗ ∗ ∗ ∗ 10 = 1, Allow Disarming Only During Arm/Disarm Windows (partition-specific).
6. Program 2∗ ∗ ∗ ∗ 11 = 0, Allow Disarm Outside Window if Alarm Occurs.
Panel will arm at 10pm Monday thru Saturday with no warning and Only Master/Manager can disarm between 10pm
and 6am.
To also Disable the Master/Manager from Disarming between 10pm and 6am All Master/Manager codes will only work
between 6am and 10pm Monday thru Saturday. They will not work on Sunday or Holidays.
1
. Enter program mode Installers code + #80
2. Enter 'Time Windows' and Create window 03 for 6:00am-10:00pm, enter 00 + ∗ to exit Time Windows
3. Do not Quit Menu Mode, go to Access Sched.
4. Create Access Sched 01 by assigning Window 03 to A1 Monday thru Saturday. Exit Program mode
5. Assign all Master and Manager Codes to Access Schedule 01 when user codes are assigned.
Open and Closed window can be removed from schedule for Saturday to prevent regular users (if they are enabled for
this particular partition) from being able to disarm on Saturday, and window can be removed from Limit Access Group 1
for Saturday to prevent Master/Manager Access on Saturday.
1 Enter the program mode Installer's code + #80.
2. Go to O/C Schedules.
3. Enter Vault Partition, go to Saturday and enter 00 for OP and CL window.
4. Go to Access Schedules.
5. Enter Schedule 01, go to Saturday and enter 00 for Window A1. Exit program mode.
Create selected Holidays in Holiday Programming and assign to all partitions. Holiday window in Open/Close Schedule
remains empty to prevent regular users (if they are enabled for this particular partition) from being able to disarm on
Holidays, and Limit Access Group 1 Holiday Window can remain empty to prevent Master/Manager Access on Holidays.
1. Enter program mode Installers code + #80.
2. Go to Holidays.
3. Enter Selected Holiday dates.
4. Exit program mode.

Limitation of Access Schedules

Limitation of Access is a means by which a user's access code is limited to working during a certain period of time. The
system provides eight Access Schedules, each of which consists of two time windows for each day of the week and two
time windows for holidays (typically, one for an opening time window and the second for a closing time window). A user,
required to follow a schedule, would be assigned to an access group of the same number (e.g., schedule 1= group 1).
The user's access code is assigned to a group when that user is added to the system. If no limitations apply, enter 0.
6-13