VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
Features
Hardwire and Optional Expansion Zones
•
Provides nine hardwire zones.
•
Supports up to 16 2-wire smoke detectors on zone 1.
•
Automatically resets 4-wire smoke detectors using the J7 output when a code + off is entered.
•
Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm. This
feature requires a 4204 Relay Module.
•
Provides tamper supervision on the hardwire zones.
•
Supports up to 241 additional expansion zones (119 for the VISTA-128BPT) using a built-in polling (multiplex) loop.
•
Supports up to 249 wireless zones (127 for the VISTA-128BPT) (fewer if using hardwire and/or polling loop zones).
The 5881ENHC RF Receiver, 5869 Holdup Switch Transmitter and 5817CB Wireless Commercial Household
U L
Transmitter are listed for UL Commercial Burglary applications. All other RF receivers and transmitters are not listed
for UL Commercial Burglary applications.
U LC
Wireless devices are not ULC Listed and cannot be used for ULC Installations.
•
Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display
or sound the alarm).
•
Provides three keypad panic keys: 1 + ∗ (A), ∗ + # (B), and 3 + # (C).
U L
Use of Remote Interactive Service (Total Connect) is not permitted in UL installations.
•
NOTE: If using Total Connect Remote Interactive Services, the virtual keypad must be assigned to a burglary
partition, and the GOTO feature (program field 2∗18) must be "0" (disabled) for partition 1 (the fire partition) so that
the Fire system cannot be accessed remotely. This is the system default setting.
•
Anti-Mask is used if a zone type 04 (interior) or 10 (interior with delay) and input type 06 (serial poll) are selected.
The trouble report code is used to report the masking.
•
A Smart contact option that may be selected for devices that support this feature such as the 5193SDT Smoke
Detector or PIRs.
•
Battery sensing hardware that can sense when the battery voltage is too low and prevents deep discharging from
not occurring.
Peripheral Devices
•
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
•
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
•
Provides 96 outputs using 4204 Relay Modules and V-Plex Relay Modules that can activate outputs in response to
system events (alarm condition), at a specific time of day, at random times, and manually using the #70 Relay
Command Mode.
•
Supports the ADEMCO 4146 Keyswitch on any one of the system's eight partitions.
Arming/Disarming and Bypassing
•
Can arm the system with zones faulted (Vent Zone). These zones are automatically bypassed and can be
programmed to automatically unbypass when the zone restores.
•
Can arm with entry/exit and interior type zones faulted (Arm w/Fault). These zones must be restored before the exit
delay expires, otherwise an alarm is generated.
•
Vent zones cannot be used in UL installations.
U L
•
You must disable the Force Arm option (used in conjunction with the Arm w/Fault option), in UL installations.
U LC
You must disable the Force Arm option (used in conjunction with the Arm w/Fault option), in ULC Installations.
•
Provides global arming capability (ability to arm all partitions the user code has access to in one command).
1-2