Adding A Master, Manager, Or Operator Code - Honeywell VISTA-128BPT Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

Adding a Master, Manager, or Operator Code

During user code entry, normal key
depressions at other keypads in a partition are
ignored. However, panic key depression
causes an alarm and terminates user entry.
Enter Installer Code † + [8] + new user no. (002-250)
+ new user's code
PROMPT
User Number = 003
Enter Auth. Level
Open/Close Rep.?
0 = NO , 1 = YES
Group Bypassing?
0 = NO , 1 = YES
Access Group?
Enter 0-8
RF Button ?
0=NO , 1=YES
Enter Button ZN #
(001-087)
Multi-Access ?
0 = NO , 1 = YES
Global Arm ?
0 = NO , 1 = YES
Part. 2 – SHOP ?
0 = NO , 1 = YES
Part. 1 A0* WHSE
User 003 Auth=3G.
EXPLANATION
Enter the level number as follows:
1 =
Master
2 =
Manager
3 =
Operator Level A
4 =
Operator Level B
5 =
Operator Level C
6 =
Duress
Keypad then prompts for Open/Close reporting option for this user.
Press 0 (NO) or 1 (YES), depending on whether or not arming/disarming by this user will trigger Opening
and Closing reports. This prompt appears only if the Installer Code is used to add a user.
Enter 1 (YES) to allow this user to perform group bypasses. Enter 0 (NO) this user will not be able to perform
group bypasses.
NOTE: In addition to enabling the user for group bypassing, the user must also have access to the
partition(s) containing the zones being bypassed and have global arming capability.
If access schedules have been programmed, this prompt appears. Enter the user's access group number (1-
8) if this user should have limited access to the system. Enter 0 if no access group should be assigned.
If a 5800 Series button transmitter has been enabled for arming/disarming functions, and is not assigned to
a user, this prompt appears. Press 0 (NO) or 1 (YES).
If you answered "yes" to the RF button question, the zone number for the button is requested. Enter any
one of the zone numbers assigned to the button transmitter as AWAY, STAY, or DISARM. The system then
assigns all buttons of the transmitter to this user number.
Press 0 (NO) if the user is to have access to this partition only. Press 1 (YES) if the user is to have access
to more than one partition. If NO, the program exits this mode. If YES, the keypad prompts for the Global
Arm option for this user.
Press 0 (NO) or 1 (YES), depending on whether this user will be allowed to arm more than one partition via
Global Arm prompts.
The keypad now prompts for the user's access to the next partition.
Press 0 (NO) or 1 (YES), depending on whether this user will have access to the displayed partition number.
If NO, the keypad displays this prompt for the next partition number in sequence.
If YES, the keypad prompts for the following:
User's authority level in the displayed partition (see Authority Level prompt above).
Open/Close option for this user in the displayed partition (see Open/Close prompt above).
Global Arm option for this user in the displayed partition.
When all partitions have been displayed, the keypad will scroll through all partitions to which access has
been assigned, and will display the user number, authority level, open/close and global arm options that
were programmed for each partition to which the user was granted access.
Note that the "G" following the authority level indicates that the global arm feature is enabled for this user in
the displayed partition, and that the period at the end of the second line indicates Open/Close reporting is
enabled for this user in the displayed partition. The [*] indicates the partition from which the user may be
changed or deleted.
Section 9 – User Access Codes
† Or Master or Manager Code, but the code must be a
higher level of authority than the code being changed
(e.g., a Manager Code can add an Operator-level Code,
but cannot add a Master or another Manager Code).
Keypad prompts for the authority level for this user.
NOTE: All references to the number of user codes
pertain to the VISTA-250BPT. The VISTA-128BPT
allows only 150 user codes.
9-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia

Table of Contents