SIA CP-01 Quick Reference Chart

The minimum required system for SIA CP-01 is a VISTA-128BPTSIA Control, one of the following keypad
models; 6160, TUXS, TUXW, 6280S, or 6280W and a UL Listed Bell.
Item
Feature
∗09
Entry Delay # 1
∗10
Exit Delay #1
∗11
Entry Delay # 2
∗12
Exit Delay #2
∗28
Power Up in Previous
State
∗57
Dynamic Signaling
Priority
∗84
Swinger Suppression
∗88
Abort Window Time
(for non-fire zones)
Exit Time Reset
1∗21
Cross Zoning
1∗22 – 1∗25
Call Waiting Defeat
1∗42
Abort Verify
1∗61
Zone
Auto Stay Arm or
Programming
Occupied Premises
Auto Stay
Zone, Zone
type 04 has
this feature
enabled by
default
Range
02 – 15 multiplied by 15
seconds
00 = 240 sec (4 minutes)
03 – 15 multiplied by 15
seconds
02 – 15 multiplied by 15
seconds
00 = 240 sec (4 minutes)
03 – 15 multiplied by 15
seconds
0 = no
1 = yes
0 = primary dialer
1 = Communicator as
first reporting destination
01-06 = 1–6 alarms
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
0 = no
1 = Resets Exit Delay to
programmed value after
zone is closed and then
faulted prior to end of
exit delay.
Zone 001 – 250
000, 000 = Disabled
0 = no
1 = yes
0 = Disable
1 = Enable
0 = Disable
1 = Enable
Shipping
Default
30 Seconds`
60 Seconds
30 Seconds
60 Seconds
Yes
0 (primary dialer)
2 alarms
30 Seconds
1 (Enabled)
Disabled
Disabled (0)
Enabled
1 (Enabled)
SIA
Requirement*
At least 30 Seconds **
60 Seconds
At least 30 Seconds **
60 Seconds
Yes
0 (primary dialer)
1 alarm
At least 15 Seconds **
1 (Enabled)
Enabled and two (or
more) zones
programmed
Enabled if user has
call waiting
Enabled
Enabled
vii