Honeywell VISTA-128BPT Installation And Setup Manual page 80

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
ACTION CODES
61=Access Point Group Grant
62=Access Point Group Grant
w/Override
63=Access Point Group
Protect
64=Access Point Group
Bypass
65=Access Point Group Lock
66=Access Point Group Exit
77=Access Point Group
Enable
78=Access Point Group
Disable
67=Access Point Partition
Grant
68=Access Point Partition
Grant w/Override
69=Access Point Protect by
Partition
70=Access Point Bypass by
Partition
71=Access Point Lock by
Partition
72=Access Point Exit by
Partition
73=Access Point Trigger On
74=Access Point Trigger Off
PROMPT
01 Time Window ?
00:00
00:00
01
01 Active time ?
0
Days ? MTWTFSSH
Hit 0-8 x
x
Quit ?
1 = YES 0 = NO
0
6-12
EXPLANATION
Actions 61-66 and 77-78
If you selected actions 61-66, the prompt at the right appears. Enter the
group number.
Press [∗] to accept entry. The "Time Window ?" prompt appears.
Actions 67-72
If you selected actions 67-72, the prompt at the right appears. Enter the
partition to which the action applies. Enter 0 to select all partitions. Enter a
partition number again to deselect it.
Press [∗] to accept entry. The "Time Window ?" prompt appears.
Actions 73-74
If actions 73-74 were selected, the prompt at the right will be displayed. Enter
the trigger number.
Press [∗] to accept entry. The "Time Window ?" prompt appears.
EXPLANATION
Enter the time window number (01-20) for which this timed event is to occur. As the number is keyed in, the
actual time that has been stored for the time window number is displayed.
Press [∗] to accept entry.
Enter the activation time from 1-10 (listed below). As the number is keyed in, the activation time is
displayed. The choices are:
1: Trigger at the start of the window.
2: Trigger at the end of the window.
3: Take effect only for the duration of the window.
4: Trigger at both the start and the end of the window. Example: coffee break buzzer.
5: Random trigger, up to 30 minutes, after the start of the window.
6: Random trigger, up to 30 minutes, after the end of the window.
7: Take effect only for the duration of the window, but random start and end the window up to 30 minutes.
Press [∗] to accept entry.
The system then asks for which days the event is to be activated.
Press 0 to toggle all days on or off; or press keys 1-8 to toggle the letter "x" under the day on or off (Monday
= 1, Holiday = H = 8).
When all entries have been made, the "TIMED EVENT #?" prompt is displayed again.
Repeat the procedure for each timed event for the installation.
Enter 0 at the "Quit ?" prompt to return to the main menu choices and continue programming. Enter 1 to quit
Scheduling Menu Mode.
ACTION SPECIFIER
01
GROUP #
00
PART? 12345678
HIT 0-8
X X
01 TRIGGER #
00

Advertisement