Advertisement

Step
Action
1
Enter Output Programming in the #93 Menu
Mode.
2
Program all the information for the relay.
3
Select the output type: ECP (1) (4204).
See Output Programming in the Programming Guide
for a detailed explanation.
Using the VISTA-128BPT/VISTA-250BPT for
Stand-Alone Access Control
The VISTA-128BPT/VISTA-250BPT can be used for
access control without interfacing to VistaKey. A user
can trigger an access point (i.e., door strike) for 2
seconds by entering User Code + [0]. To program the

Programming for ECP Communicator

Program the Communicator in Device
Programming in the #93 Menu Mode
Programming.
Field ∗56: Selects the time the panel should wait
before it attempts to send a message to the second
destination.
VISTA-128BPT/VISTA-250BPT for Stand-Alone access
control, perform the following steps:
Step
Action
1
Enter Output Programming in the #93 Menu
Mode.
2
Program the output type as 1, or 2.
3
For type 1, program the ECP address and
relay number.
4
For type 2, program the house and unit codes.
5
Program the relay number in field 1∗76
(partition-specific).
See Output Programming in the Programming Guide
for a detailed explanation.
Field ∗57: Select the initial reporting destination
for messages.
Field ∗58: Select events for the primary sub's ID
Field ∗59: Select events for the secondary sub's ID.