Can Quick Exit an armed premises without having to disarm and then rearm the system.
U L
Quick Exit is not permitted for use with the VISTA-128BPT/VISTA-250BPT Control Panel in a UL installation.
Can be armed in one of three STAY modes or Instant modes, automatically bypassing specific burglary zones
regardless of the zone response type.
Can automatically bypass specific zones if no one exits the premises after arming (Auto-STAY). Auto-STAY will not
occur if the system is armed via an RF transmitter, scheduling, access control, keyswitch, RS232 (TB4) automation
or downloading.
Can bypass a group of zones with one set of keystrokes.
Supports Exit Error Logic, whereby the system can tell the difference between a regular alarm and an alarm caused
by leaving an entry/exit door open. If the system is not subsequently disarmed, faulted E/E zone(s) and/or interior
zones are bypassed and the system arms.
Supports Recent Close report, which is designed to notify the central station that an alarm has occurred within 2
minutes after the exit delay has expired.
Partitioning
Can control eight separate areas independently, each functioning as if it had its own separate control.
Provides a Common Lobby partition, which can be programmed to arm automatically when the last partition is
armed, and to disarm when the first partition is disarmed.
Provides a Master partition (9), used for the purpose of viewing the status of all partitions at the same time.
Can display fire, burglary, panic, and trouble conditions at all other partitions' keypads (selectable option).
Scheduling
U LC
Scheduling cannot be used for ULC Installations.
Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights).
Provides access schedules (for limiting system access to users by time).
Provides an End User Output Programming Mode, allowing the user to control outputs.
Access Control
Supports up to 15 VistaKey modules (15 access points) (VISTA-128BPT supports 8 modules), which are used for
access control. It is a single-door access control module.
Support up to 500 access cards (250 in VISTA-128BPT).
Can store access control events in the event log.
System Communication
Supports ADEMCO Contact ID; ADEMCO 10-Digit Contact ID and 4+2 Express formats.
The system is shipped defaulted for Contact ID communication. It is the only format capable of uniquely reporting all
250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped with the
MX8000 receiver or equivalent to fully support all new VISTA-128BPT/VISTA-250BPT report codes. If you need to
update your MX8000 receiver, contact your distributor.
Supports Dynamic Signaling feature, which prevents redundant signals being sent to the central station when both
the built-in dialer and Communication Devices are used.
Provides the Dialer Queue Report in the event of a loss of communications between the dialer and the central
station, i.e. telco loss. The total events that will be queued up are 128 (91 Burg + 37 Life Safety). A Dialer Queue
Overflow report (E354) will be sent if the report queue goes beyond its limits. Note that: Life Safety includes Fire,
CO, 24 HR Silent/Audible/Auxiliary, and Duress. Life Safety events may go beyond 37 (up to 128) if there are no
Burg events in the queue.