FIELD
TITLE and DATA ENTRIES
∗ ∗ ∗ ∗ 22
Keypad Panic Enables (partition-
specific)
0 = disable
1 = enable
∗ ∗ ∗ ∗ 23
Multiple Alarms (partition-
specific)
0 = disable
1 = enable
∗ ∗ ∗ ∗ 24

Ignore Expansion Zone Tamper

0 = disable (tamper detection)
1 = enable (no tamper detection)
∗ ∗ ∗ ∗ 26

Intelligent Test Report

0 = disable
1 = enable

Test Report Interval

∗ ∗ ∗ ∗ 27
Enter 0001-9999 for the test report interval in
hours.
Enter 0000 for test reporting.
∗ ∗ ∗ ∗ 28
Power-Up in Previous State
0 = disable
1 = enable
∗ ∗ ∗ ∗ 29
Quick Arm (partition-specific)
0 = disable
1 = enable
∗ ∗ ∗ ∗ 30
Phone Linecut Detect
0 = disable
1 = enable
∗ ∗ ∗ ∗ 31

PABX Access Code

Enter 00-09; B-F (11-15)
∗ ∗ ∗ ∗ 32
Primary Subscriber's Account
Number (partition-specific)
Enter 00-09; B-F (11-15)
∗ ∗ ∗ ∗ 33

Primary Phone Number

Enter 0-9; #11 for ∗, #12 for #, #13 for a 2-
second pause.
EXPLANATION
If enabled, the keypad panics (zones 995, 996, and 999) may be used in this
partition. There are three entries in this field, one for each panic.
If enabled, allows more than one alarm sounding for a given zone during an
armed period.
NOTE: that multiple alarm soundings will not occur more frequently than
allowed by the programmed alarm sounder duration. This has no impact on
the number of communication messages transmitted.
Must be 1 for UL installations.
If disabled, the system monitors the tampers on expansion zones.
NOTE: Only applicable to certain polling loop sensors with tamper switches or
5800 Series transmitters.
Must be 0 for UL installations.
If enabled, no test report is sent if any other type of report was sent since the
last test report.
If disabled, test reports are sent at the set intervals, regardless of whether or
not any other report has been sent.
Must be 0 for UL applications.
If a test report is desired, enter a test code in Report Code Programming in
#93 Menu Mode. Set first test report time in field ∗83.
Maximum Test report interval is 0024 for UL installations.
If enabled, the system, upon power-up, reverts to its status prior to a complete
power loss.
If disabled, the system always powers up in a disarmed state.
NOTE: Neither authority level 0 nor 5 can be used to disarm the system if the
control powers up armed.
Must be 1 for UL applications.
If enabled, allows arming of the burglary system in AWAY, STAY, INSTANT,
or MAXIMUM mode by using the [#] key instead of the user code.
NOTES:
When armed, the system reports closing as User 0 if Open/Close reporting for
User #2 (typically a Master level user) was enabled for a given partition.
If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot
disarm the system.
Select phone linecut detection.
This field is used to enter up to four 2-digit numbers representing the prefix
needed to obtain an outside telco line. If not required, enter nothing and
proceed to next field.
Enter a 4- or 10-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 4-digit account number is to be used, enter data
only in the first four locations, and enter * in the fifth location.
Enter the primary central station phone number, up to 17 digits. This is the
phone number the control will use to transmit Alarm and status messages to
the central station. Do not fill unused spaces.
NOTE: Backup reporting is automatic only if a secondary phone number is
entered.
Section 5 – Data Field Descriptions
5-3