Service and Troubleshooting
View active/historical alerts
In the timeline, click the left or right arrow to scroll to the alert, and then select the alert
icon for details.
Figure 7-3:
A. Play or pause
B. Left arrow
C. Timeline slider
D. History alert icon
E. Drag anywhere in the timeline to move the timeline forward or backward.
F. Right arrow
G. Export echo curves
H. Options
Play echo curve movies
1.
2.
Export echo curve movies
1.
2.
3.
4.
5.
6.
7.
8.
100
Level Trend Timeline
Set the start point.
a. Click the left or right arrow, or drag anywhere in the timeline.
b. Click the start point in the timeline.
Select Play, or drag the timeline slider to move one frame at a time.
Under Service Tools, select Echo Curve.
Select Export.
Type your desired file name.
Browse to the desired directory, and then select Save.
Under Time range, select Last 1 hour, Last 3 hours, Last 24 hours, or User defined
range.
If User defined range is selected, specify the start and end times.
Select Export.
Select Back.