Form 5596
November 2006
CERTIFICATION
TYPE
BODY
4211, 4221
4210, 4211,
4212, 4215,
4220, 4221,
FM
4222
4211, 4221
4210, 4211,
4212, 4215,
4220, 4221,
4222
CERTIFICATE
TYPE
4211, 4221
ATEX
4211, 4221
ATEX Intrinsic Safety, Dust (Type 4211
and 4221)

Special Conditions for Safe Use

This equipment is intrinsically safe and can be used
in potentially explosive atmospheres.
The apparatus mus only be connected to a certified
associated intrinsically safe equipment and this
combination must be compatible as regards intrinsic
safety rules.
The electrical parameters of the associated
intrinsically safe equipment must not exceed any of
the following values:
Uov30 V, lov150mA, Pov1W
Maximal ambient temperature:
−40_C to +71_C.
Temperature classification is as follows:
T5 at Tav + 40_C
T4 at Tav + 71_C
Refer to table 7 for additional approval information,
and figure 27 for ATEX approval nameplates.
Table 6. Hazardous Area Classifications for United States—FM
CERTIFICATION OBTAINED
(Intrinsic Safety)
Class/Division
Class I,II,III Division 1 GP A,B,C,D,E,F,G
per drawing GE16019
(Explosion Proof)
Zone
Class I Zone 1 AEx d IIC T5
Class/Division
Class I, Division 1 GP A,B,C,D T5
Class I Division 2 GP A,B,C,D T4
Class II Division 2 GP F,G T4
Class II Division 1 GP E,F,G T5
Table 7. Hazardous Area Classifications—ATEX
CERTIFICATION OBTAINED
II 1 G D
Gas
EEx ia IIC T4/T5—Intrinsic Safety
Dust
t 71°C)
T81C (T
amb
II 3 G D
Gas
EEx nL IIC T4—Type n
Dust
t 71°C)
T81C (T
amb
4200 Series Transmitters
TEMPERATURE
ENTITY RATING
V
= 30 Vdc
max
I
= 150 mA
max
P
= 1.0 W
T4 (T
i
amb
C
= 5 nF
i
L
= 0 mH
i
− − −
T5 (T
amb
− − −
T4 (T
amb
− − −
T5 (T
amb
TEMPERATURE
ENTITY RATING
U
= 30 Vdc
i
I
= 150 mA
i
T4 (T
amb
P
= 1.0 W
i
T5 (T
amb
C
= 5 nF
i
L
= 0 mH
i
− − −
T4 (T
amb
ATEX Type n, Dust (Type 4211
and 4221)
Special Conditions of Safe Use
No special conditions for safe use.
Refer to table 7 for approval information, and figure
27 for ATEX approval nameplates.

Mechanical Connections

Sliding-Stem Actuator Mounting,
Type 4210, 4211, 4212, and 4215
Use the following general procedures and figures 15,
16, 17, and 18 to mount the transmitter on
sliding-stem actuators, standard stroke up to 105
mm (4.125 inches) travel.
Refer to figure 15 for key number locations for this
example.
1. Install the transmitter on the mounting plate
(key 21) with two cap screws (key 32).
2. Bolt the stem mounting bracket and spacer
(keys 34 and 39) to the stem connector on the
ENCLOSURE
CODE
RATING
t 71°C)
4X
t 71°C)
4X
t 71°C)
4X
t 71°C)
4X
ENCLOSURE
CODE
RATING
t 71°C)
IP66
t 40°C)
t 71°C)
IP66
7

Hide quick links:

Advertisement